Technical data
4Commissioning
CamTel
svr
25
4 Commissioning
This chapter describes the basic procedure for successfully commissioning
yourCamTel
svr
andprovidestipsforconfigurationanddesignstrategies.The
online manual for CamControl LITE and CamControl PRO software
provides further information on configuration software and the menus
relevant to configuring your application. For clearness, the following
information refers to CamControl LITE software. CamControl PRO
software providesidenticalfeatures and can be used for commissioning as
wellwithoutany
limitation.
4.1 First steps
1. InstallCamTel
svr
asdescribedinchapter"Systemdescription", section
"Mountingandsettingup"andswitchthedeviceon.(see“Mounting
andsettingup”onpage12)
2. Connect all input and output lines to your CamTel
svr
unit now, if
possible.Allrequiredplugsareincludedinthescopeofdelivery.Refer
tochapter"Pinassignmentandfunctionality".Fortheinstallationofa
camera system with PTZ control, additional information is required.
Pleaserefertotheinstallationinstructionsofthecameramanufacturer
andtherespectivesupplementarydocumentsbyHeiTel. Also
observe
the information provided in chapter"PTZ control"(see“PTZ control”
onpage31)
3. InstalltheCamControl LITEsoftwareforoperation,alarmverification,
and configuration from the installation CD. Please observe the
installationinformation intheonline manualof the same name. This
manualisincludedintheinstallationCD.
4. Connect the CamTel
svr
to the PC with the CamControl LITE
software.Useeitherthenullmodemorthenetworkcable.Bothcables
areincludedinthedeliveryofyourCamTel
svr
.
5. Start the CamControl LITE software and use option "Connect" to
connecttoyourCamTel
svr
unit,observingthefollowing:
■ If you use a null modem cable: Open CamControl LITE
software in offline mode. Go to menu item Settings,menu
itemPort A,menuitemMode.ActivateoptionNull modem.
■ Ifyou useanetworkcable:OpenCamControl LITEsoftware
inofflinemode.GotomenuitemSettings,menuitemPort
A, menu item Mode. Activate option TCP/IP. In addition,
include your CamTel
svr
unit as new transmitter in the
transmitter list, including the CamTel
svr
TCP/IP address. The
factorysettingsare:IPaddress=192.168.31.95;subnetmask
=255.255.255.0;ActivatethetransmitterlistwithoptionDial.
6. RefertotheCamControl LITEsoftwareonlinemanualforallfurther