Technical data

3Systemdescription
CamTel
svr
21
musthaveadurationofatleast500mstoallowforpositivedetectionby
thedeviceanddistinctionfrom"swishcontacts".
Error relay
The device configuration allows designation of integrated relays as error
relays in order to report certain operating statesor malfunctions using dry
contacts.Thestatusoftheerrorrelaythenalwayscorrespondstothestatus
oftheErrorLEDonthefrontofCamTel
svr
:
ErrorifLEDon,thenerrorrelayenergised
Noerror,ifErrorLED off,thenerrorrelayde-energised
Examplesforpossibleerrorsreportedbyerrorrelay:
FaultyDSP
Faultyvideodecoder
Faultyclockmodule
Sabotage protection
Theerrorrelayispulledinidle-noerror.Thereforetheerrorrelaycanbeused
assabotagedetector,asitautomatically fallsoffintheeventofpowerfailure
(e.g. caused by cut power lines). Depending on the error relay wiring, an
interruptionoftherelaylineitselfcanbe
reportedaswell.
Modem/null modem
Use
1. Connecting external dialup devices for remote connections to
CamControlunits.Usetheconnectingcableprovidedwiththedialup
adapter.
2. SerialdirectconnectiontoaCamControlunitwiththeprovidednull
modemcable.Thisconnectionmodeisrecommendedfor
commissioningandservice.
Configuration
CamControl LITE or CamControl PRO software allow you to set the
connection speed for remote and direct connections. In addition, AT
commands can be entered for initialisation and dialling of external dialup
adapters,orfordefiningdialmode.Refertotherespective softwaremanual
formoreinformation.
Pin assignment for
RS-232 interface
Connectorendview/9pin
Sub-Dplug
Thereisa theoreticalpossibilitythat sabotageprotection will not workif
errorrelayswitchingisnotconsistentwiththeoperatingmode.
Pin Type Function
Code
designation
1 Input DataCarrierDetect DCD
2 Input ReceiveData RxD