User guide
Table Of Contents
- I
- Introduction
- Distance Solution
- Installation
- Step One: Ensure That Attached Devices Function Properly
- Step Two: Set Up Device Router
- Step Three: Clear the Node Mapping Table of the Host Router
- Step Four: Set Up Host Router
- Step Five: Run Connection Check
- Step Six: Run Subsystem Device Check
- Step Seven: Set Operating Mode
- Step Eight: Power Down Sequence (optional)
- Step Nine: Power Up Sequence (optional)
- Operation
- Installation
- SCSI-Fibre Channel Fabric Connectivity A5814A-003
- System Maintenance
- Serial Port Diagnostics
- Brocade 2800 Fabric Switch
- RAID Manager XP
- Appendix A: SCSI-Fibre Channel Router Specifications
- Appendix B: Diagnostic Status Codes
- Index

Hewlett-Packard SCSI-Fibre Channel Router Installation and User Guide
Revision 2.1.0 Page
40
Appendix A: SCSI-Fibre Channel Router Specifications
Applications
Provides connectivity between SCSI High Voltage Differential (HVD) and Fibre Channel equipment and vice versa.
Hardware Features
SCSI Connectivity
• Protocol: SCSI-2 Ultra-Wide Differential (40MB/sec); supports either initiator (host) or target (device) protocol.
• Data Transfer Rate: 40MByte/sec (per SCSI-FC Router per SCSI Channel) burst
• SCSI-2: 68-pin High Density
• Device Support: One HP e3000 or HP9000 or Windows NT and One HP XLR1200
• Supports: Command Processing, Tagged Queuing, Scatter/Gather, Disconnect/Reconnect, Synchronous and Asynchronous
data transfer
Fibre Connectivity
• Protocol: ANSI Fibre Channel (FC-PH) and ANSI Fibre Channel Arbitrated Loop (FC-AL)
• Classes of Service: Class 3
• Topology: FC-AL (private or public), Point to Point
• Data Transfer Rate: 100MBytes/sec (per SCSI-FC Router per Fibre channel)
• Port Speed: 100Mbytes/sec
• Short Wavelength Fibre Channel Cable
Data Rate: 100Mbytes/sec burst
Cable: 50 or 62.5 micron fibre optic
Distance: 500 m (1640 ft) or 172m (564 ft)
Connector: Dual SC
Attachment
• Compatible with
--Distance Solution
HP e3000 (Operating Systems MPE/iX 5.5 and MPE/iX 6.0)
--SCSI-FC Connectivity
HP e3000 (Operating Systems MPE/iX 5.5 and MPE/iX 6.0)
HP9000 (Operating Systems ?.? and ?.?)
Windows NT
• HP XLR1200 system
Technical Specifications
Maintenance
• External Serial Port: RJ-11 connector (57K baud rate)
Environment
• Operating Temperature: 0ºC (32ºF) to 40ºC (104ºF)
• Storage Temperature: -40ºC (-40ºF) to 75ºC (167ºF)
• Relative Humidity: 10% to 95% non-condensing
Power
• AC Input: 100 - 240 VAC, 50 - 60 Hz
• DC Output: 5V, 40W
• Max. Inrush Current: 30A @ 115VAC or 60A @ 230VAC
• Current: 0.75 - 0.50 A
Tabletop Dimensions
• Height: 7.62 cm (3 in)
• Width: 10.795 cm (4.25 in)
• Depth: 31.115 cm (12.25 in)
• Weight: .8 kg (3.97 lb)
Note: The SCSI-FC Router can also be installed into a
rackmountable SCSI-Fibre Channel Router enclosure.
User Interface
• LED indicators
• Serial Port
Emissions
• Acoustic: 50dB (A)
Safety Certifications and Compliance
• IEC 950:1991 + A1, A2, A3, A4 / EN 60950:1992 + A1, A2, A3, A4
• IEC 825-1:1993 / EN 60825-1:1994 + A11, Class 1
EMC Certifications and Compliance
• CISPR 22:1993 +A1, A2 / EN 55022:1994 +A1, A2 - Class A1
• EN 50082-1:1992
IEC 801-2:1991 / prEN 55024-2:1992, 4 kV CD, 8 kV AD
IEC 801-3:1984 / prEN 55024-3:1991, 3 V/m
IEC 801-4:1988 / prEN 55024-4:1993, 0.5 kV Signal Lines
1 kV Power Lines
IEC 1000-3-2:1995 / EN 61000-3-2:1995, Class X, Harmonics
IEC 1000-3-3:1994 / EN 61000-3-3: 1995, Flicker