User guide
Table Of Contents
- I
- Introduction
- Distance Solution
- Installation
- Step One: Ensure That Attached Devices Function Properly
- Step Two: Set Up Device Router
- Step Three: Clear the Node Mapping Table of the Host Router
- Step Four: Set Up Host Router
- Step Five: Run Connection Check
- Step Six: Run Subsystem Device Check
- Step Seven: Set Operating Mode
- Step Eight: Power Down Sequence (optional)
- Step Nine: Power Up Sequence (optional)
- Operation
- Installation
- SCSI-Fibre Channel Fabric Connectivity A5814A-003
- System Maintenance
- Serial Port Diagnostics
- Brocade 2800 Fabric Switch
- RAID Manager XP
- Appendix A: SCSI-Fibre Channel Router Specifications
- Appendix B: Diagnostic Status Codes
- Index

Hewlett-Packard SCSI-Fibre Channel Router Installation and User Guide
Revision 2.1.0 Page
39
Next, proceed to the Config tab and create a config
name called MPE_Config1.
Drag or click on red from the Zone Selection list and
click Add Member> to the MPE_config1 Members list.
Do the same with the blue zone.
Check the Enable Config box and click the Apply
button.
You have now created two zones, red and blue, where
each zone operates independently from each other.
7 RAID Manager XP
RAID Manager XP is a utility program that controls features on the XP family of storage arrays. A version
of this utility runs under the MPE/iX operating system and when connected to the A5814A router, passes
commands to a Command Drive or CMD on the XP512. Commands are then intercepted by the XP and
are then executed.
The CMD Lun address must be configured as Lun 0, on the XP, and must have a target and lun address
of zero (0.0) on the HP e3000. Verify this through the Mapper utility on the HP e3000.