4 Press and release the right button. The display now shows the P value (default is 1.0). Wait approximately
two seconds for the display to return to “P.
5 Press and release the left button. Display now reads “I.
6 Press and release the right button. The display now shows the I value (default is 0.00). Wait approximately
two seconds for the display to return to “I.
7 Press and release the left button. Display now reads “d.
8 Press and release the right button. The display now shows the D value (default is 0.5). Wait approximately
two seconds for the display to return to “d.
9 Press and release the left button. Display now reads “F.04.
10 Pressing the left button again at this time loops the display back to “F.03” (step 2 above). You may continue
to cycle through the settings as desired by repeatedly pressing the left button. And you can check each of
those five settings by pressing and releasing the right button.
11 When all settings are verified as being correct, release the buttons and turn the DD off. Next time you turn
the DD on, the last-selected settings will be in use.
PID Interface Flowchart
Up and down arrows
change the parameter
PID power button displays the parameter’s value
The “P” button
selects the parameter
Default PID Settings
(presented here for your future reference)
P = 1.0 I = 0.0 D = 0.5 F.04 = 19 F.03 = F (centigrade F.04 value is 10)