29. When the drain water is clean and free from the acidic taste of the cleaner, turn the
power switch to 0 and UNPLUG the machine.
30. Remove the reservoir, the reservoir platform, and the two screws holding the divider
panel. Tip the panel back so you can reach the water sensor probe. After mentally noting
the length of probe that extends up and out of the boiler, loosen the small nut that holds
the probe, and pull the probe straight up and out of the boiler. Wipe it clean with a cloth.
If necessary, light use of a scrubbing pad is okay. Replace the probe in the boiler
making sure it sits at its original depth. Reconnect the autofill sensor wire on the boiler
and remove the twist tie from the anti-vacuum valve.
CAUTION: Failure to reconnect the autofill wire will cause your machine to behave
erratically and can cause damage not covered by the warranty.
31. Move the partition panel back into place and fasten with the two upper Phillips screws.
32. Tip the machine onto its back and install the two small Phillips screws in the bottom that
hold the internal partition.
33. Place the machine upright and replace the outer cover and fasten the 6 Phillips screws
that hold it in place. Take care not to pinch the reservoir hoses.
34. Replace the water reservoir platform, the water reservoir, reinstall the water softener if
so equipped, wipe the two hoses clean, and replace them in their proper location in the
reservoir. Refill the reservoir with the water normally used in the machine. If you
removed heavy mineral deposits during the descaling process, think seriously about
improving your water source or water treatment system. Also check the hardness of
your water at more frequent intervals.
CAUTION: Exercise extreme caution during the following step. You will be dealing with
boiling water gushing out of the hot water spout. Use necessary protection.
35. Plug the machine back in and turn the power switch to position I. The pump should not
start. Place a suitable container under the hot water spout and open the hot water valve.
Turn the switch to position II. As the machine heats up and pressure builds, some of the
excess water in the boiler will be displaced by steam. When the pump begins to operate,
signifying that the water has been lowered to about the correct level, close the hot water
tap. The pump should stop shortly after closing the tap.
WARNING: Do not leave the machine unattended until the proper water level in the boiler
has been verified!
36. When the machine reaches operating temperature, bleed steam off the boiler to assure
that the water level is correct. If a lot of water comes out, then the water level is too
high. Repeat step 35. If this problem continues, consult your retailer.