enough cold water to reach the proper ratio. Once the solution is cool, use it to fill the
water reservoir at least ½ full.
10. Plug the machine in and only turn the power switch to Position I.
Allow the boiler to
fill. Do not continue to the next step until the pump stops. Please note: Some of the
earlier versions had a time-out function which will disengage power to the autofill
box after 1 minute. If that is the case in your unit, and the autofill shuts off on its
own after 1 minute, turn the power switch to 0 and the back to I and it will
reactivate the autofill. This safety function will continue engaging throughout the
whole process, so keep in mind that you’ll have to reactivate the autofill when
necessary.
WARNING: In many of the following steps, such as when pumping descaler through the
grouphead and removing the hoses from the water tank, splashing acid can create a safety
hazard. Gloves, eye protection, and work-area protection are required.
11. Place a suitable container under the grouphead, turn on the brew function, and run about
8 ounces of descaling solution through the grouphead. This also ensures that the
thermosyphon pipes, the heat exchanger, and the internal components of the grouphead
will be descaled.
12. Snap the blind filter into the portafilter handle and simulate backflushing the machine.
Turn on the brew function and allow it to run for about 10 seconds after the pressure
reaches its peak. This will force descaler through the over-pressure relief valve. You
will see the liquid flowing back into the reservoir through the secondary hose. When
that takes place, turn the machine to 0 and UNPLUG the power cord. Leave the hoses in
place and move the reservoir off to the side of the machine and lift off the reservoir
platform.
13. Remove the two Phillips head screws holding the top of the divider panel and swing it
back and off the machine. Take care not to stress the wires attached to the water-level
microswitch which is attached to the panel.
14. Remove the water level sensor wire
by loosening the screw inside the
plastic housing shown in the
picture. Leave it disconnected for
now. This will fool the boiler into
thinking that it is low on water and
needs to be refilled. Set the wire off
to the side where it cannot
accidentally connect with any metal