Manual
Table Of Contents
- SmartOTDR Mainframe
- Table of Contents
- About This Guide
- Chapter 1 Safety information
- Chapter 2 Introducing the SmartOTDR
- Chapter 3 Starting up
- Chapter 4 Setting-up the SmartOTDR
- Chapter 5 Optical options
- Chapter 6 Microscope application
- Chapter 7 Connectivity
- Establishing connection
- Remote Control
- Smart Access Anywhere
- Connection modes
- Pre-requisite for using the Smart Access Anywhere Application
- Downloading the VIAVI application on PC
- Downloading the VIAVI application on Tablet/ Smartphone
- Launching the SmartAccess Anywhere application
- Using Remote screen and File Transfer applications
- Working with files and directories on SmartOTDR
- Connection information and settings
- Data Transfer
- VNC
- Smart Access Anywhere
- Stratasync
- Chapter 8 File management
- Chapter 9 Technical specifications
- Chapter 10 Options and accessories
- Chapter 11 Maintenance and Troubleshooting
- Maintenance procedure
- Recycling Information
- Troubleshooting
- General information on warranty
- Index
Chapter 9 Technical specifications
Characteristics of the options
100 User Manual 7SMART102 Rev006
• Display resolution: 0.01 dB / 0.01nW
• Linearity: ± 0.5 dB
6
Dual-Band Power Meter (through filtered OTDR port) -
118FA65PPM version only
• Calibrated Wavelengths : 1310 / 1490 / 1550 / 1625 / 1650 nm
• Selectable Wavelengths :
– Power Meter Mode (1 channel): 1310 to 1500 nm and 1540 to 1650 nm
–
PON Power Meter Mode (2 channels): 1310 / 1550 nm ; 1490 / 1550 nm ; 1490
/ 1577 nm
• T
one detection : 270 Hz, 330 Hz, 1 kHz, 2 kHz, and TWINTest
• Max Input Power Level: +26 dBm???
• Measurement Range:
– 1310 to 1500 nm : -35 to + 5 dBm
–
1540 to 1650 nm : -35 to +23 dBm
• Accurac
y at calibrated wavelengths: +/- 0.5 dB (at -30 dBm)
3
• Display resolution: 0.01 dB / 0.01 nW
• Linearity: +/- 0.5 dB
5
• Channels isolation from external source:
– 1310/1490: > 40dB
– 1550 to 1650: > 20dB
Characteristics of the options
VFL
• Wavelength: 650 nm
• Length of fiber: up to 5 km
• Class 2 laser (standards EN60825-1 and FDA21 CFR Part 1040.10).
5.Except 1650 nm
6.from -50 dBm to -5 dBm