Manual
Table Of Contents
- SmartOTDR Mainframe
- Table of Contents
- About This Guide
- Chapter 1 Safety information
- Chapter 2 Introducing the SmartOTDR
- Chapter 3 Starting up
- Chapter 4 Setting-up the SmartOTDR
- Chapter 5 Optical options
- Chapter 6 Microscope application
- Chapter 7 Connectivity
- Establishing connection
- Remote Control
- Smart Access Anywhere
- Connection modes
- Pre-requisite for using the Smart Access Anywhere Application
- Downloading the VIAVI application on PC
- Downloading the VIAVI application on Tablet/ Smartphone
- Launching the SmartAccess Anywhere application
- Using Remote screen and File Transfer applications
- Working with files and directories on SmartOTDR
- Connection information and settings
- Data Transfer
- VNC
- Smart Access Anywhere
- Stratasync
- Chapter 8 File management
- Chapter 9 Technical specifications
- Chapter 10 Options and accessories
- Chapter 11 Maintenance and Troubleshooting
- Maintenance procedure
- Recycling Information
- Troubleshooting
- General information on warranty
- Index
Chapter 9 Technical specifications
Characteristics of the Source (standard) and Power Meter (optional)
User Manual 7SMART102 Rev006 99
Vibration
The SmartOTDR resists the following vibration tests:
• Complete test comprising 6 cycles along each of the x, y and z axes.
• One cycle of 5 to 200 Hz and back to 5 Hz with a sweep duration of one minute/
octave.
• 3 mm amplitude displacement test, for the range 5 Hz to 15 Hz.
• 3g acceleration test for the range 16 Hz to 200 Hz.
Flammability
The SmartOTDR housing (in ABS, type V0) does not propagate fire.
Characteristics of the Source (standard) and Power
Meter (optional)
Source
• Output Power Level
1
: -3.5 dBm
• Stability long term (8h): ± 0.05 dB
2
Broadband power Meter (through non-filtered OTDR
port)
3
Specifications given for 25°C, after 20 minutes stabilization and zero setting.
• Calibrated wavelengths: 1310 / 1490 / 1550 / 1625 / 1650 nm
4
• Selectable Wavelengths: 1310 to 1650 nm
• Tone detection: 270Hz, 330Hz, 1 kHz, 2 kHz and TWINTest
• Max Input Power Level: +10 dBm
• Measurement Range: -55 to 0 dBm
• Accuracy at calibrated wavelengths: ± 0.5 dB (at -30 dBm)
5
1.+/- 1 dB
2.After 30min light source stabilization time
3.Not available on 118FA65 version
4.1625 nm ,not calibrated on 138FB65 version