Datasheet

VIAVI Solutions
Data Sheet
VIAVI
Specications for SmartPocket V2
TM
Light Sources
OLS-34V2 OLS-35V2 OLS-36V2 OLS-38V2
Wavelengths
850, 1300 nm 1310, 1550 nm 850, 1300 nm 1310, 1550 nm 1310, 1550, 1625 nm
Wavelength Accuracy - 20 / + 40 nm ± 20 nm -20 / + 40 nm ± 20 nm ± 20 nm
FWHM Spectral Width < 170 nm < 5 nm < 170 nm < 5 nm < 5 nm
Output Level Typ. - 20 dBm Typ. -3 dBm Typ. -20 dBm Typ. -3 dBm Typ. - 6 dBm
Short Term Stability ± 0.02 dB
within 15 min
± 0.02 dB
within 15 min
± 0.02 dB within 15 min
± 0.02 dB
within 15 min
Long Term Stability ± 0.05 dB
within 8 hrs.
± 0.05 dB
within 8 hrs.
± 0.05 dB within 8 hrs.
± 0.05 dB
within 8 hrs.
Power Meters and selective PON Power Meter
OLP-35V2 OLP-35SC OLP-38V2 OLP-37XV2
Photo Diode InGaAs InGaAs InGaAs (coated) InGaAs
Spectral Range
Broadband (800...1650 nm)
Passband
(12701500 nm,
15401650 nm)
Wavelength Setting 8001650 nm,
step size 1 nm
8001650 nm,
step size 1 nm
8001650 nm,
step size 1 nm
1490 nm, 1577 nm
Resolution 0.01 dB, 0.001 µW 0.01 dB, 0.001 µW 0.01 dB, 0.001 µW 0.01 dB, 0.001 µW
Measurement Range for
Power Level
-65+10 dBm -65+10 dBm -50+26 dBm -45…+13 dBm
Max. Power Level +16 dBm +16 dBm +27 dBm +15 dBm
Measurement Uncertainty ± 0.2 dB (± 5%)
at ref. conditions
± 0.2 dB (± 5%)
at ref. conditions
± 0.2 dB (± 5%)
1
± 0.5 dB (± 12%)
at ref. conditions
Number of Calibrated
Wavelengths
8
(850, 980, 1310,
1490, 1550, 1577, 1625,
1650 nm)
8
(850, 980, 1310,
1490, 1550, 1577,
1625, 1650 nm)
8
(850, 980, 1310,
1490, 1550, 1577,
1625, 1650 nm)
2
(1490, 1577 nm)
Tone Detection 270 Hz, 330 Hz,
1 kHz, 2 kHz
270 Hz, 330 Hz,
1 kHz, 2 kHz
270 Hz, 330 Hz,
1 kHz, 2 kHz
270 Hz, 330 Hz,
1 kHz, 2 kHz
Auto functions
2
Auto-λ / Multi-λ Auto-λ / Multi-λ
3
¹When used with SC/PC connectors
²When used with VIAVI light sources
³In Broadband mode

Summary of content (3 pages)