Manual

 Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing
Clean
Clean Bulkhead with the IBC™
CLEAN
Guide Cap Nozzle extender lockNozzle
Guide cap cover
. Select the appropriate cleaning tool for
the connector type.
. Pull off the guide cap cover.
Guide cap cover
Dry Clean
Impact
Wet
Dry Clean
. Insert the cleaning tool into the
bulkhead adapter and push the cleaner
into the bulkhead two times (two clicks).
For hard-to-reach places, push the nozzle
extender lock and pull the nozzle out.
. Determine whether clean or dirty.
y If clean, do not touch it and CONNECT
y If dirty, either repeat step  or go to step 
. Apply a fiber optic cleaning
solution onto a clean fiber wipe.
. Dab the cleaning tool onto the
wet area of the wipe to moisten
the cleaning tip, then go to step .
Repeat steps 3, 4, and 5 if necessary.
Push into bulkhead
two times (two clicks)