OLP-37XV2 SmartPocket™ V2 Optical Power Meters User manual BN 2335/98.11 2021.
Please direct all enquiries to your local Viavi sales company. The addresses can be found at: www.viavisolutions.com/en-us/contact-sales-expert The description of additional features of the device can be found at: www.viavisolutions.
CONTENTS CONTENTS I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 OLP-37XV2 Optical Power Meter . . . . . . . . . . . . . . . . . . . . . . 5 User manual update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Symbols used in this user manual . . . . . . . . . . . . . . . . . . . . . 7 SAFETY I NFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 GETTING S TARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTENTS ORDERING INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . 29 Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 P RODUCT R EGULATORY COMPLIANCE . . . . . . . . . . . . . . .
1 I NTRODUCTION OLP-37XV2 OPTICAL P OWER METER 1 I NTRODUCTION OLP-37XV2 Optical Power Meter The OLP-37XV2 is a specialized optical power meter designed for use cases such as system/network qualification, subscriber activation, and troubleshooting of passive optical network (PON). The instrument performs wavelength selective optical power measurements suitable for testing G-PON networks, as defined in ITU-T G.983/4 or IEEE 802.3ah and XGS-PON networks, as defined in ITU-T G.9807.1 respectively.
1 I NTRODUCTION U SER MANUAL UPDATE User manual update If the operating instructions about features provided by your device are missing, please visit the Viavi web site to check if additional information is available. To download the latest operating instructions: 1. Visit the Viavi web site at www.viavisolutions.com. 2. Search for SmartPocket V2. 3. Open the download area and download the operating instructions if available.
SYMBOLS USED 1 I NTRODUCTION IN THIS USER MANUAL Symbols used in this user manual Various elements are used in this user manual to draw attention to special meanings or important points in the text. Symbols and terms used in warnings The following warnings, symbols and terms are used in this document in compliance with the American National Standard ANSI Z535.6-2011: NOTICE Follow the instructions carefully to avoid damage to or destruction of the instrument.
1 I NTRODUCTION SYMBOLS USED IN THIS USER MANUAL Warning format All warnings have the following format: WARNING Type and source of danger Consequences of ignoring the warning J Action needed to avoid danger. The following character formats are used in this user manual: I Requirement This requirement must be met first; e.g. I The device is switched on. J 1. 2. Italics Instruction Follow the instructions given (the numbers indicate the order in which the instructions should be followed); e.g.
2 SAFETY I NFORMATION SYMBOLS USED IN THIS USER MANUAL 2 SAFETY I NFORMATION J All safety information for your device can be found in the printed booklett “ Safety, Disposal and Environmental Protection“ provided with your device. J Carefully read and follow all instructions given there. J The booklett “ Safety, Disposal and Environmental Protection“ is attached to this pdf. You can open it from the attachment window or by clicking the thumbnail on the left.
3 GETTING S TARTED U NPACKING THE DEVICE 3 GETTING STARTED Unpacking the device Packing material We suggest that you keep the original packing material. It is designed for reuse (unless it is damaged during shipping). Using the original packing material ensures that the device is properly protected during shipping. Checking the package contents Your device is shipped with the following accessories: • 2.
3 GETTING S TARTED D EVICE OVERVIEW Device overview 2 1 3 4 6 1 2 3 4 5 6 OLP-37XV2 5 Test head cover Fixed SC adapter Display Key pad Representation in the user manual: Context sensitive keys (here left key is selected) [] [MODE] [ G] [ E] Mode/Settings key Save/Results key Power key USB interface For power supply and measurement data downloads and updates.
3 GETTING S TARTED P OWER S UPPLY Keys The key pad contains two types of keys: • Contex t sensitive keys: The functions of these keys depend on the selected mode or menu and is shown in the display above the key. • Function keys: The functions of these keys are always the same and shown on the key itself. Key usage (first and second function levels) The function keys and the context sensitive keys in certain modes have two function levels. A second function level is indicated by two cascading frames.
3 GETTING S TARTED P OWER S UPPLY Battery operation WARNING Dangers in handling batteries Handling batteries may be dangerous. Please note the following safety instructions. J Please note the battery operation safety information in the booklett “ Safety, Disposal end Environmental Protection” provided with your device. Replacing the batteries J Do not replace individual batteries. Always change both batteries at the same time. J Always use batteries of the same type; i.e.
3 GETTING S TARTED P OWER S UPPLY Protecting the environment Please dispose of any unwanted dry batteries and rechargeable batteries carefully. They should also be removed from the instrument if it is to be scrapped. If facilities in your country exist for collecting waste or for recycling, please make use of them rather than throwing the batteries in the normal trash. You will often be able to return used batteries to the place where you purchase new ones.
4 OPERATION SWITCHING THE DEVICE ON / OFF 4 OPERATION Switching the device on/off The OLP-37XV2 has two battery power modes: Mode Icon Description Permanent ON (PERM) The device is switched on permanently. Automatic OFF (ECON) The device switches off 20 minutes after the last operation. This function is only available when the device is powered from batteries. To switch the device on/off : J Press [ E] to switch the device on/off.
4 OPERATION D ISPLAY ELEMENTS Display elements The following elements can be found in the display. 1 2 3 Display of one value (here G-PON) Display of both values in Dual mode 1 – Status bar PON Mode Further modes for future use. Bluetooth® is active Bluetooth connction allows for data transfer via the MobileTech app (for future use). 7:15 Real Time Clock Time can be changed via the settings menu. Battery status in PERM power mode: Device remains switched on.
4 OPERATION SETTINGS MENU Settings menu The following settings can be changed in the settings menu. J To open the settings menu long press [MENU]. OLP-37XV2 Item Settings Description Hour 1...12 Minute 1...59 Year 2020...2030 Month 01...12 J Press [ ] to change setting: – Press once to change one step at a time. – Hold down the key to increase the step change rate. Day 01...
4 OPERATION SELECTING A OPERATION MODE Selecting a operation mode The OLP-37XV2 provides three operation modes with following displays: • G-PON: Gigabit Passive Optical Network measurement at 1490 nm • XGS-PON: 10-Gigabit-Capable Symmetric Passive Optical Network measurement at 1577 nm • Dual: Display of G-PON and XGS-PON simultaneously To select a operation mode: J Press [] to select a mode. Fig.
SELECTING A 4 OPERATION DISPLAY MODE Selecting a display mode The OLP-37XV2 provides following display modes: • dBm/Watt: Display of absolute power level • Loss: Display of power level relative to a reference value • PF Abs: Pass/Fail indication based on an absolute power threshold • PF Loss: Pass/Fail indication based on a relative power threshold To select a display mode: J Press [] to toggle between the displays modes.
4 OPERATION LOSS MODE Loss mode In Loss mode the power level relative to a reference value is displayed. The reference value can be set by defining the current power level as the reference value [Abs>Ref]. J Press [] to display relative power level. Setting the reference level I Absolute power level mode or Loss mode is selected. J Press [Abs>Ref]. The current power level is set as the new reference level. NOTE: 20 The reference level can be stored for both wavelength separately.
4 OPERATION PASS/FAIL MODE Pass/Fail mode An integrated pass/fail analysis feature simplifies standard conformity testing and provides unambiguous measurement result presentation. The OLP-37XV2 provides two Pass/Fail modes: • PF Abs: Pass/Fail indication based on a absolute power threshold • PF Loss: Pass/Fail indication based on a loss threshold To select a Pass/Fail mode: J Press [] until PF Abs or PF Loss is displayed.
5 M EMORY M ANAGEMENT GENERAL INFORMATION 5 M EMORY M ANAGEMENT General information The OLP-37XV2 allows you to save the measured power level values in a data memory and recall them as required. Up to 1000 results can be stored. NOTE: See also “Specifications” on page 27 for additional data management tools. Storing measurements J Press [ G] to save the current result. The result is saved when "Saving ..." appears on the display and below the name of the currently saved data.
5 M EMORY M ANAGEMENT D ELETING MEASUREMENTS 2. Press []/[] to browse through the list. 3. Press [ ] to open the highlighted entry. The selected measurement data is displayed. 4. Press [ ] to return to the list or, press []/[] to show next/previous result or press [MODE] to exit. Deleting measurements I The device shows the list of saved measurements. 1. If you want to delete a single entry, use []/[] to select it. 2. Long press [ ] to open the sub menu. 3.
6 DATA E XPORT AND F IRMWARE U PDATE USB AND S MART R EPORTER 6 DATA E XPORT AND F IRMWARE U PDATE The USB interface or the Bluetooth® interface can be used for data export and firmware update. USB and SmartReporter When using the USB interface the SmartReporter allows you to easily transfer stored measurement data to a PC and to update the firmware. The SmartReporter reporting tool always contains the latest Firmware Revision for all your SmartPocket™ V2 devices.
7 M AINTENANCE CLEANING THE TEST PORT 7 M AINTENANCE WARNING Invisible laser radiation Maintenance or cleaning of the instrument while it is connected or operating may damage the instrument or injure you. J Make sure that the instrument is switched off and disconnected from all power sources and optical radiation sources before maintenance or cleaning. J Do not open the instrument for maintenance or service. Service shall be performed by Viavi trained personnel only.
7 M AINTENANCE CLEANING THE INSTRUMENT Cleaning the instrument If the device gets dirty through use, you can clean it using a soft cloth moistened with a mild solution of detergent. NOTICE Water and cleaning fluids The instrument may be damaged or destroyed if water or cleaning fluids penetrate it. J Make sure that water or cleaning fluids do not get inside the instrument.
8 SPECIFICATIONS OLP-37XV2 8 SPECIFICATIONS OLP-37XV2 G-PON (1490 nm downstream) Power measurement range Maximum permitted input level Spectral pass band Power uncertainty 1) At -2 dBm, at 23 °C ± 3 °C, at nominal wavelength -45 to +13 dBm +15 dBm 1260 to 1500 nm ±0.5 dBm1) XGS-PON (1577 nm downstream) Power measurement range Maximum permitted input level Spectral pass band Power uncertainty 1) At -2 dBm, at 23 °C ± 3 °C, at nominal wavelength -45 to +13 dBm +15 dBm 1540 to 1650 nm ±0.
8 SPECIFICATIONS GENERAL SPECIFICATIONS EMC and safety Environmental conditions Electromagnetic compatibility (EMC) Device safety Operating temperature range Storage and transport Altitude Pollution degree Ingress protection Relative humidity up to +31 °C Absolute humidity > +31 °C EN 61326-1:2013 EN 61010-1:2010 -10 to +55 °C (14 to 131 °F) -40 to +70 °C (-40 to 158 °F) 2000 m max. (6500 ft. max.) 2 IP44 15 to 85 % 1 to 29 g/m3 Occasional condensation is tolerable as a limit condition.
9 ORDERING INFORMATION D EVICES 9 ORDERING INFORMATION Devices OLP-37XV2 Optical Power Meter (G-PON, XGS-PON) OLP-37XV2 Calibration report OLP-37XV2 BN 2333/90.03 Accessories Cleaning materials, power supplies OCK-10 Optical cleaning kit Cleaning tape for optical connectors Spare optical cleaning tape NiMH rechargeable batteries, Mignon AA, 1.2 V (2 batteries required) AC adapter OLP-37XV2 BN 2229/90.21 BN 2229/90.07 BN 2229/90.08 BN 2237/90.02 BN 2302/90.
10 P RODUCT R EGULATORY COMPLIANCE A CCESSORIES 10 P RODUCT R EGULATORY COMPLIANCE J All information about the product regulatory compliance can be found in the printed booklett “ Safety, Disposal and Environmental Protection“ provided with your device.
10 P RODUCT R EGULATORY COMPLIANCE A CCESSORIES OLP-37XV2 31
North America Latin America China Germany User manual SmartPocketTM V2 Optical Power Meters OLP-37XV2 +1 844-468 4284 +1 954 688 5660 +86 21 6859 5260 +49 7121 86 0 Viavi product specifications and descriptions in this document are subject to change without notice. © 2021 viavisolutions.