Manual

 Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing
Test: Reference Power Measurement
Reference Power Measurement (single-mode fiber) Using a VIAVI Optical Light Source
TEST
. Inspect and, if necessary, clean both ends of the
reference fiber jumper [J].
. Inspect and, if necessary, clean the OLS port.
. Connect J to the OLS port.
. Inspect and, if necessary, clean both ends of the
reference fiber jumper [J].
. Connect J to the OPM port.
. Inspect and, if necessary, clean both ends of the
loopback device.
. Connect J and J to the loopback device using a
bulkhead adapter.
. Power on the OLS and set the wavelength to Auto-
lambda ( –  nm).
. Touch [SET REF] on the OLP to reference out the
power level at  –  nm until . dB is
displayed.
10. Set the OLS to Multi-lambda mode for operation.
11. Disconnect the loopback and adaptor for use at the
remote end.
Female bulkhead inspection
B
Male patch cord inspection
PP
VIAVI OLS-35 with jumpers and loopback device and OPM (OLP-82)
Inspect
Inspect
PP
PP
Reference
fiber [J2]
Reference
fiber [J1]
Loopback
Inspect Inspect
Inspect
B
PP
PP
PP
PP
PP
PP
NOTE: DO NOT disconnect the reference fiber J1
from the OLS port as reference will be lost.
NOTE: If the test procedure does not
include a loopback, then it can be
removed from the test setup.
PP
PP