Datasheet

© 2019 VIAVI Solutions Inc.
Product specifications and descriptions in this
document are subject to change without notice.
fivp-ds-fit-tm-ae
30162642 902 0219
Contact Us +1 844 GO VIAVI
(+1 844 468 4284)
To reach the VIAVI office nearest you,
visit viavisolutions.com/contact
viavisolutions.com
VIAVI Solutions
Specifications
General
Power source 2 x AA alkaline batteries
Wavelength range 780 to 1800 nm
Battery life > 70 hours
USB type 2.0
Screen size (W x H) 3.7 x 3.1 cm
Storage temperature 20 to 70° C
Operating temperature 0 to 50° C
LFI
Dimensions 216 x 60 x 38 mm
(8.5 x 2.35 x 1.5 in)
Weight 135 g (4.8 oz) with two AA alkaline batteries
Detection sensitivity 20 dBm @ 1310 nm,
-30 dBm @ 1550 nm
Insertion loss (typical) 1310 nm: < .2 dB,
1550 nm: < 2 dB
Detected wavelengths 850 to 1700 nm
Detected tones 270 Hz, 330 Hz, 1 kHz, 2 kHz
*
Standard cable
diameter range
250 µm - 3 mm
OPM
Dimensions 171 x 42 x 25 mm (6.8 x 1.7 x 1.4 in)
Weight 100 g (3.5 oz) with two AA alkaline batteries
Connector input 1.25 mm and 2.5 mm available
Measurement types dB, dBm
Detectable optical
power range
–65 dBm to +10 dBm
Max. permitted input
level
+23 dBm
Intrinsic uncertainty
1
±0.20 dB (± 5%)
Linearity
1
±0.06 dB (–50 dBm to +5 dBm)
Standard wavelength
settings
850, 980, 1300, 1310, 1490, 1550, 1625 nm
Wavelength and
modulation
270 Hz, 330 Hz, 1 kHz, 2 kHz
1300, 1310, 1490, 1550,
1625 nm
–60 to +10 dBm
850, 980 nm –55 to +10 dBm
1. Under the following reference conditions: –20 dBm (CW), 1300 nm ± 1 nm, 23°C ± 3K,
45 to 75% rel. humidity, 9 to 50 µm fiber
*Note that 2 kHz tone detection is not available below -45 dBm
Features and Components
Cable Alignment Groove
LFI Release/Attach Screw
Detachable LFI Head
3.7cm x 3.0cm LCD
Power Button
SafeChek™
Trigger
for Live Fiber
Identifier
USB Input for
Connection to PC for
use with  fiber
analysis software
Inter-Changeable
Input for Power
Meter
Data STORE and
RECALL Controls
OPM Controls
Ordering Information
Description Part Number
Live Fiber Identifier with removable LFI attachment, 2.5 mm and 1.25mm OPM connector interfaces; USB cable; software; carrying case FI-60
Optical Power Meter with 2.5 mm and 1.25 mm connector interfaces; USB cable; software; carrying case VP-60A
Optical Power Meter with 2.5 mm connector interface; USB cable; software; carrying case VP-60
Attachment Head; Live Fiber Identifier, connects to VP-60 VPP-LFI
Adapter, for 1.25mm (LC, MU) for VP Series OPM VPP-UPP12
Adapter, for 2.5mm (FC, SC, ST) for VP Series OPM VPP-UPP25