Specifying test settings
Before you begin testing, make sure the test settings on the SmartClass Triple Play Services match
the settings of the line and network configuration you are testing.
To specify test settings
1 From the IP Video menu, select Video Setup, and then specify the settings.
Configuring the settings can be done one of two ways:
– Press a number on the key pad that corresponds to the setting you want to configure.
– Use the arrow keys to highlight the setting you want to change, and then press the OK key.
Press the Cancel key to exit a menu.
The following table describes the settings.
2 To specify settings for a particular stream, do the following:
a From the Video Setup menu, select the Stream Setup for the desired stream, for example
Stream 1 Setup.
These settings are only available in Terminate Mode.
TIP:
Test configurations can be stored for easy recall and use (see “Managing test configurations” on
page 29).
NOTE:
You must specify the interface settings before specifying Video settings. For example, you must
configure the Data, LAN, and other applicable settings for a xDSL line.
Setting Description
Mode Select Terminate or Monitor mode.
Analysis Type Select Normal or UT Starcom.
Use UT Starcom when analyzing Rolling Stream video streams.
IGMP Version If you are in Terminate mode, specify the version of IGMP signaling being
used on the circuit: version 2 or version 3.
RTSP Port Enter the RTSP port number.
This is the port where RTSP signaling communication takes place in a partic-
ular network.
RTSP Vendor Enter the RTSP vendor.
This setting is only relevant in Terminate mode.