Product specifications

VT8235 V-Link South Bridge
Revision 1.22 October 24, 2002 -114- Device 17 Function 6 Modem Controller Registers
Offset 42 Function Enable............................................. RO
This register is controlled through function 5 but may be read
from function 6.
7-6 Reserved ........................................ always reads 0
5 Function 5 Config Reg Rx2C Writable............. RO
0 Device 17 Function 5 Rx2C-2F RO ...... default
1 Device 17 Function 5 Rx2C-2F RW
4-0 Reserved ........................................ always reads 0
Offset 44 MC97 Interface Control................................RW
7 AC-Link Interface for Slot-5 (Modem)
0 Disable .................................................. default
1 Enable
6 Secondary Codec Support
0 Disable .................................................. default
1 Enable
5 Function 6 Config Reg Rx9-B Writable
0 Device 17 Function 6 Rx9-B RO .......... default
1 Device 17 Function 6 Rx9-B RW
4 Function 6 Config Reg 2Ch Writable
0 Device 17 Function 6 Rx2C-2F RO ...... default
1 Device 17 Function 6 Rx2C-2F RW
3 Sync
This bit reports whether there is activity in function 6
(modem). When function 5 (audio) enters low-power
state and wants to gate bit-clock, software needs to
check this bit to see whether bit-clock can actually be
gated, as function 6 shares the same bit-clock.
0 Function 6 activity in progress that requires
bit-clock
1 Function 6 does not need bit-clock so bit-clock
can be gated
2-0 Reserved ........................................ always reads 0
Offset 48 Volume Change Rate Control .......................RO
This register is controlled through function 5 but may be read
from function 6.
7-4 Volume Change Rate...........................................RO
This field controls the volume change rate in the
sample rate converter
0000 Volume Adjust Every Frame (sync cycle)...def
1111 Volume Adjust Every 16 Frames (sync cycles)
3 Sync .........................................................RO
This bit reports whether there is activity in function 5
(audio). When function 6 (modem) enters low-power
state and wants to gate bit-clock, software needs to
check this bit to see whether bit-clock can actually be
gated, as function 5 shares the same bit-clock.
0 Function 5 activity in progress that requires
bit-clock
1 Function 5 does not need bit-clock so bit-clock
can be gated
2-0 Reserved ........................................................ RW
Offset 49 S/PDIF Control...............................................RO
This register is controlled through function 5 but may be read
from function 6.
7-4 Reserved .........................................................RO
3 DX3 (DirectSound) Channel S/PDIF Support ..RO
This bit controls whether DirectSound Channel 3 is
used as S/PDIF support
0 Disable...................................................default
1 Enable
2 Reserved .........................................................RO
1-0 S/PDIF Data Slot Select.......................................RO
00 Slot 10/11............................................... default
01 Slot 3/4
10 Slot 7/8
11 Slot 6/9
Offset D3-D0 Power Mgmt Capability..........................RO
31-0 Power Mgmt Capability....always reads 0002 0001h
Offset D7-D4 Power State ............................................. RW
31-2 Reserved ........................................always reads 0
1-0 Power State (D3 / D0 Only)