User`s manual
Chapter 3
Inverter Selector: IVDD_SEL
IVDD is the VCC selector jumper to determine the input voltage of the panel
inverter for panel’s back-light.
Setting 1 2 3 4 5 6
+5V ON ON ON ON OFF OFF
+12V OFF OFF ON ON ON ON
Panel Power Selector: LPC
The LPC connector contains the VCC selector jumper to determine the panel’s
signal voltage.
Setting 1 2 3 4 5 6 7 8
+3.3V ON ON OFF OFF ON ON OFF OFF
+5V OFF OFF ON ON OFF OFF ON ON
COM1 Power Selector: J2
J2 is a VCC selector jumper to determine the input voltage for COM1
connector.
Setting 1 2 3
+5V ON ON OFF
+12V OFF ON ON
+5V:
+12V:
135
135
+5V:
132
+12V:
132
+3.3V:
+5V:
2468
2468