User`s manual

Pulse 1: Positive pulse
Pulse 2: Negative pulse
Signal 3:Toggle
Signal 3 (toggle) is for switching ON and OFF the external
device. If the external device is ON, user can control the output
port to turn it OFF. If the external device is OFF, user can
control the output port to turn it ON
- Pulse setup:
High Period: The default frequency is 1 second while the upper
limit is 999 seconds.
Low Period: The default frequency is 1 second while the upper
limit is 999 seconds
Pulse number: The default number is 1 while the upper limit is
99.
- OK: Click OK to confirm.
7.1.5.3 Input Port Mode Setup
Click on an input point number, the input port mode dialog will pop up
for setting:
- Input port Name: Setup Input port name.
- Port Type: Trigger mode selection.
Turn on/off Alarm: Active or inactive set alarm function for
Chateau system. When this port triggered, the alarm status will
turn off if it was on before. And vise versa.
Trigger alarm: When alarm detected signal, it will triggered the
set alarm action.
- Activate Input Point timetable: Activate timetable can be set for
each input point individually. Other then the timetable set, the
alarm will not be activating when the input point is triggered.
Setting of the timetable is same to the setting of the camera’s
alarm timetable. Please refer to
Chapter 6.1.2 Activate condition
for more information.
69