User`s manual
Table Of Contents
- System Specification
- System Introduction:
- System Front Panel:
- USB
- Number 1-8 Buttons
- Number 9 Button
- Number 0 Button
- Power Indicator()
- Recording Indicator()
- Playback Indicator()
- Record/ Switch to Recording Display Button:
- Setting / List Button
- Leftward Button / Playback Backward
- Upward button / Step Playback / Pause Playback
- Rightward Button / Playback Forward / Output Control
- Select / Backup Button
- Playback Button
- Subtract 1 / Next / Slow Speed Playback
- Downward Button / PIP Function
- Add 1 / Last One / Fast Speed Forward
- Cancel / Stop / Alarm Log Button
- System Back Panel:
- Hard Disk Installation:
- System Front Panel:
- System Setting
- Record
- Playback
- PIP Function
- Alarm Log
- I/O
- File Backup
- Network Function
- VG Player

low potential, then the system will triggered the alarm.
When input potential is set at low, it means it is low potential under normal
condition, you will require to use NC (Close) device. When sensor
triggered, it will become open circuit, and then the input terminal will detect
high potential, then the system will triggered the alarm.
Input terminal’s triggered potential means enable when set at “---“
Note: Wrong setting will cause error alarm triggered. It is suggest
using the device using NC. This means that when it is triggered, or
connection cut off, it will trigger alarm.
8.2 Output Control Setup
Output control is mainly controlling the relay output. Relay output itself is
only the on/off device. It is not with any power signal output. So other than
connect it to the needed devices, necessary power will need to connect as
well.
If output setting is “ON”, this means under normal condition, relay output is
open loop circuit, after activated; relay output will become close loop
circuit.
If output setting is “OFF”, this means under normal condition, relay output
is close loop circuit, after activated; relay output will become open loop
circuit.
Output not controllable when output setup is “---“
8.3 Output Control
When output control button is pressed, the following picture will
be shown:
39
MUTE/OUTPUT CONTROL
1. MUTE
2. OUTPUT1 OFF
3. OUTPUT2 OFF
4. OUTPUT3 OFF
5. OUTPUT4 OFF