User`s manual
Table Of Contents
- System Specification
- System Introduction:
- System Front Panel:
- USB
- Number 1-8 Buttons
- Number 9 Button
- Number 0 Button
- Power Indicator()
- Recording Indicator()
- Playback Indicator()
- Record/ Switch to Recording Display Button:
- Setting / List Button
- Leftward Button / Playback Backward
- Upward button / Step Playback / Pause Playback
- Rightward Button / Playback Forward / Output Control
- Select / Backup Button
- Playback Button
- Subtract 1 / Next / Slow Speed Playback
- Downward Button / PIP Function
- Add 1 / Last One / Fast Speed Forward
- Cancel / Stop / Alarm Log Button
- System Back Panel:
- Hard Disk Installation:
- System Front Panel:
- System Setting
- Record
- Playback
- PIP Function
- Alarm Log
- I/O
- File Backup
- Network Function
- VG Player

in the Internet. Defaulted host name is VGN8C/VGN16C. Users
can change the name easier to recognize. You will require setting
the “Connect Server” to “off” before setup/alter the host name.
Connect Server: System will connect to the server according to
the setting when it is set as on. If set at off, then system will not
connect to server.
Server: For Network connection, system will need to connect to
the PC running the Server program. Server address is the IP
address for that PC. Server IP address can also be a domain
name. For Example, the PC running the server program does not
have a fix IP address; you can apply a Dynamic Domain Name
from the supplier to connect the hosts on the network. Domain
name will require DNS setup.
Server Port: It is suggest setting the communication port for the
Server program as defaulted 40000 when setting the remote
connection. Please do not change it if not necessary. If alteration
is a must, then you will require changing all three communication
ports to the same value for VGuard N, Server Program and
Remote server for Chateau V5.0.
Disconnect Alarm (Output): When connect server is set as on,
if system is not able to make connection to server, an alarm
output notice will be made. User will be able to use this output
signal to control external alarm equipment. There are 4 sets of
relay output for selection. (Relay equipment are optional)
Connection
User can use
left, right to enter connection setup
NETWORK SETUP : CONNECTION
1.LISTEN PORT 50000 50000
2.MODE LAN
3.GET IP AUTO GET IP
22
Listen Port: Listen Ports for the N Series, LAN users use the
first value; WAN users use the second value. Defaulted value is
50000. Internet connection will require changing the