Installation manual
www.desatech.com
118531-01C 33
HI
LO
O
F
F
P
I
L
O
T
O
N
Figure 58 - Removing Mounting Screws,
Regulator, Tower, and Diaphragm/Spring
Components
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
GAS CONTROL CONVERSION
Convert gas control by swapping out valve
regulator portion of gas valve.
1. Using a Torx T20 or slotted screwdriver,
remove and discard three mounting
screws, pressure regulator tower, and
diaphragm/spring components (see
Figure 58).
2. Insure that rubber gasket is properly
positioned on new pressure regulator
assembly. Install LP pressure regulator
assembly to valve using the new mount-
ing screws supplied with the kit. Tighten
screws securely (approximately 25 in-lbs.)
(see Figure 59).
3. Install identication label enclosed with
gas valve regulator to valve body, where
it can easily be seen (see Figure 59).
CONVERSION
INSTRUCTIONS
Continued
O
F
F
P
I
L
O
T
O
N
Figure 59 - Installing Pressure Regulator
Assembly
Mounting
Screws
Rubber
Gasket
Identication
Label
CLEANING AND
MAINTENANCE
GLASS DOOR