VENTING INSTALLATION
NOTICE: Read these instruc-
-

These models are tested and approved for
use with DESA/Vexar (direct-vent) pipe com-
ponents and terminations.
The venting system must terminate on the
outside of the structure and can not be at-
tached to a chimney or ue system serving a
separate solid fuel or gas burning appliance.
A direct-vent appliance must have its own
venting system. DO NOT common vent this
appliance.
This model is approved to be vented either
horizontally through an outside wall or verti-
cally through a roof or chase enclosure using
the following:
When venting system terminates horizon-
tally on an outside wall, you may install
a standoff if the termination cap is to be
installed directly on a combustible nish
such as vinyl, wood, stucco, etc.
Never run the vent downward as this may
cause excessive temperatures which could
cause a re.
Vent pipe air space clearances to com-
bustibles are 1" on all sides except on the
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the
termination cap penetrates a combustible
wall, 1" air space clearance is required.
Have replace and selected vent compo-
nents on hand to help determine the exact
measurements when elbowing or offsetting.
Always use wall restops when penetrating
walls, ceilings or attic spaces.
Install horizontal venting with a 1/4" rise for
every 12" of run toward the termination.
WARNING: Read all instruc-

  
Failure to do so could result in


IMPORTANT: Do not seal vent cap to pipe.
Cap must be removable for servicing.
NOTICE: Failure to follow
these instructions will void

NOTICE: Do not seal termination

   

INSTALLATION PRECAUTIONS
Wear gloves and safety glasses for pro-
tection
Use extreme caution when using ladders
or when on roof tops
Be aware of electrical wiring locations in
walls and ceilings
The following actions will void the warranty
on your venting system:
Installation of any damaged venting com-
ponent
Unauthorized modication of the vent-
ing system (Do not cut or alter vent
components)
Installation of any component part not
manufactured or approved by DESA/
Vexar
Installation other than as instructed by
these instructions

    
    

-


 


    
   -

on the horizontal sections,
   



