VENTING INSTALLATION
NOTICE: Read these  instruc-
-
These  models  are  tested  and  approved  for 
use with DESA/Vexar (direct-vent) pipe com-
ponents and terminations.
The  venting  system  must  terminate  on  the 
outside  of  the  structure  and  can  not  be  at-
tached to a chimney or ue system serving a 
separate solid fuel or gas burning appliance. 
A  direct-vent  appliance  must  have  its  own 
venting system. DO NOT common vent this 
appliance.
This model is approved to  be vented either 
horizontally through an outside wall or verti-
cally through a roof or chase enclosure using 
the following:
•  When venting system terminates horizon-
tally  on  an  outside  wall,  you  may  install 
a  standoff if  the  termination  cap  is  to  be 
installed  directly  on  a  combustible  nish 
such as vinyl, wood, stucco, etc.
•  Never run the vent downward as this may 
cause excessive temperatures which could 
cause a re.
•  Vent  pipe  air  space  clearances  to  com-
bustibles are 1" on all sides except on the 
horizontal sections, which requires 2" clear-
ance from the top of the pipe. Where the 
termination cap penetrates a combustible 
wall, 1" air space clearance is required.
•  Have replace and selected vent compo-
nents on hand to help determine the exact 
measurements when elbowing or offsetting. 
Always use wall restops when penetrating 
walls, ceilings or attic spaces.
•  Install horizontal venting with a 1/4" rise for 
every 12" of run toward the termination.
 WARNING: Read all instruc-
  
Failure to do so could result in 
IMPORTANT: Do  not seal vent cap to pipe. 
Cap must be removable for servicing.
NOTICE:  Failure  to  follow 
these  instructions will  void 
NOTICE: Do not seal termination 
   
INSTALLATION PRECAUTIONS
•  Wear gloves and safety glasses for pro-
tection
•  Use extreme caution when using ladders 
or when on roof tops
•  Be  aware of electrical wiring locations in 
walls and ceilings
The following actions will void  the  warranty 
on your venting system:
•  Installation of any damaged venting com-
ponent
• 
Unauthorized modication of the vent-
ing  system  (Do  not  cut  or  alter  vent 
components)
•  Installation  of  any  component  part  not 
manufactured  or  approved  by  DESA/
Vexar
•  Installation  other  than  as  instructed  by 
these instructions
    
    
-
 
    
   -
on  the  horizontal  sections, 
   