Installation manual

www.fmiproducts.com
108918-01K12
10'
2'Min.
10'
3'Min.
2'Min.
3'Min.
Levelof
FlueGas
Outlet
Figure 19 - 10 Foot Rule
10 FOOT RULE
Alluegasoutletchimneyterminationsmust
extendaminimumof3feetinheightabove
highestpointwhereitpassesthroughroofand
mustbeatleast2feetabovehighestpointof
theroofthatiswithinahorizontaldistanceof
10feet(seeFigure19).
VENTING INSTALLATION
Continued
FINISHING FIREPLACE
Combustible materials, such as wallboard,
gypsumboard,sheetrock,drywall,plywood,
etc.,maymakedirectcontactwithsidesand
toparoundreplaceface.Itisimportantthat
combustible materials do not overlap face
itself.Brick,glass,tileorothernoncombustible
materials may overlap front face provided
theydonotobstructessentialopeningssuch
as louvered slots. When overlapping with
a noncombustible facing material, use only
noncombustiblemortaroradhesive.
30E-8DM
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
EFFECTIVE HEIGHT
OF TERMINATION CAP
MINIMUM
HEIGHT
11 .5 FT.
MINIMUM
UP TO
6FT. MAX.
UP TO
6FT. MAX.
HEIGHT
11 .5 FT.
MIN. HEIGHT
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.
MAX. HEIGHT
50 FT.
(ANY SYSTEM)
30E-8DM
Figure 20 - Typical Residential Installations