Instructions / Assembly
- 55 -
Cannot trigger the spray
gun.
Spray gun trigger lock is
locked.
Rotate the trigger safety lever to the unlock
position.
Paint is coming out of
the pressure control
knob.
Pressure Control Knob is
worn.
Have the sprayer serviced by a qualified repair
person.
Spray/Prime valve
actuates automatically
relieving pressure
through the Output
Prime Tube.
System is over-pressurized.
Have the sprayer serviced by a qualified repair
person.
Paint leaks down the
outside of the pump.
Pump packing seals have
worn.
Replace pump packing seals.
Motor is hot and runs
intermittently. Motor
automatically shuts off
due to excessive heat.
Damage can occur if
cause is not corrected.
Vent holes in motor
enclosure are plugged
or sprayer is covered.
Keep vent holes clear of obstructions and
overspray, and keep the sprayer uncovered
and open to air.
Extension cord is too long
or not heavy enough
gauge.
Replace the extension cord with a 12 AWG
cord.
Unregulated electrical
generator being used has
excessive voltage.
Use an electrical generator with a proper voltage
regulator. Sprayer requires a 120VAC, 60Hz,
1500-Watt generator.