Instructions / Assembly
- 35 -
7.Leads from motor to circuit board
for damaged or loose wire
connectors. Inspect wiring
insulation and terminal for signs of
overheating
7.Be sure male terminal pins
are connected and firmly
connected l female terminals.
Replace any loose terminals
or damaged wring,Securely
reconnect terminal
8.Worn motor brushes which must
be greater than 1/4 in.(6 mm)
8.Replace brushes
9.Motor brushes binding in brush
holders
9.Clean brush holders.
Remove carbon dust by using
compressed air to blow out
brush dust
10.Low stall pressure.Turn
pressure control knob fully
clockwise
10.Replace pressure control
assembly
11.Motor armature for shots by
using an armature tester (growler)
or perform spin test
11,Replace motor
Daily Maintain
Equipment lifetime is rely on daily maintain. The following respects should
be obeyed:
1. Read the Manual carefully before first using.
2. Check the electrical requirement before each working.
3.Thorough cleaning equipment and the accessories after using
4.Coil the tube after cleaning, in case of any damage.
5.Add some lubricant if long time not use
General Repair Information