Use and Care Manual

Add(+)” key to change the value. After 5
seconds without operating the key, the
system will exit and save the setting
value automatically.
6.Hold down “Subtract(-)” key and
Add(+)” key for 5 seconds at the same
time to enter the Factory parameter
setting mode, press the “Lighting key to
change the object, press “Subtract(-)” key
and Add(+)” key to change the value. The
system will exit and save the parameters
automatically after 5 seconds without any
operation of keys.
( Model:X-300)
1.Press “Left Mixing key, turn on left
mixing function, left mixing light is on.
Press “Left Mixing key again to turn off
the left mixing function.
2. Press “Right Mixing key, turn on right
mixing function, right mixing light is on.
Press “Right Mixing key again to turn off
the right mixing function.
3. Press the “Cold Drink key (a Mixing
function must be turned on, otherwise the
Cold Drink key does not work), turn on the
cold drink function, and cold drink light is
on (the compressor is powered on) or cold
drink light flashes (compressor is powered
off), then press the “Cold Drink” key again
to close the cold drink function.
4. Press the “Slush” key (a Mixing function
must be turned on, otherwise the Slush
key does not work) to open the slush
function, and slush light is on (the
compressor is powered on) or slush light
flashes (compressor is powered off), then
press the “Slush” key again to close the
slush function.
5. Press the “Lighting key to turn on the
light, and then press the “Lighting key
again to turn off the light.
6.Press Set key, enter the user parameter
setting state. At this time, press the “Set
key to change the setting object, press
“Subtract(-)” key and Add(+)” key to
change the value. After 5 seconds without
operating the key, the system will exit and
save the setting value automatically.
7.Hold down Set key and Add(+)” key
for 5 seconds at the same time to enter the
Factory parameter setting mode, press the
"Set key to change the object, press
“Subtract(-)” key and "Add(+) key to
change the value. The system will exit and
save the parameters automatically after 5
seconds without any operation of keys.
( Model:X-450)
1.Press “Left mixing key, turn on left
mixing function, left mixing light is on.
Press Left Mixing Key again to turn off
the left mixing function.
2. Press “Mid Mixing key, turn on mid
mixing function, mid mixing light is on.
Press Mid Mixing key again to turn off
the mid mixing function.
3. Press “Right Mixing key, turn on right
mixing function, right mixing light is on.
Press “Right Mixing key again to turn off
the right mixing function.
4. Press the “Cold Drink” key (a mixing
function must be turned on, otherwise the
Cold Drink key does not work), turn on the
cold drink function, and cold drink light is
on (the compressor is powered on) or cold
drink light flashes (compressor is powered
off), then press the “Cold Drink” key again
to close the cold drink function.
5. Press the “Slush” key (a Mixing function
must be turned on, otherwise the Slush
key does not work) to open the slush
function, and slush light is on (the
compressor is powered on) or slush light
flashes (compressor is powered off), then
press the Slush key again to close the slush
function.
6. Press the “Lighting key to turn on the
light, and then press the “Lighting key
again to turn off the light.
7. Press "Set” key, enter the user
parameter setting state. At this time, press
the “Set key to change the setting object,
press “Subtract(-)” key and Add(+)” Key to
change the value. After 5 seconds without
operating the key, the system will exit and
save the setting value automatically.
8.Hold down “Subtract(-)” key and
Add(+)” key for 5 seconds at the same
time to enter the Factory parameter
setting mode, press the “Set key to
change the object, press “Subtract(-)” key
and Add(+)” key to change the value. The
system will exit and save the parameters
automatically after 5 seconds without any
operation of keys.
Notice: when machine works well, please
do not changed factory settings.
1.4.3 Alarm Code Description
1) "- -": Frozen bowl alarm is given and the
compressor and motor will stop working,
and resume automatically after 10
minutes.
2)"RH": temperature sensor malfunction
alarm. Stop cooling in cold drink function
state without affecting slush function.
3)"LLL": low voltage alarm, the whole
machine stops. Turn off the power and
check the power supply. Restart machine
after voltage is stable. If it show “LLL
frequently, We suggest you connect a
voltage stabilizer.
2. Safety
2.1 General Safety Rules
1. Read the entire manual carefully
2. The power cord must meet local safety
standards