Instructions / Assembly
- 20 -
Device Status
Three-color indicator status (green light:
standby, yellow light: charging, red light:
failure)
Standby mode
Green light steady on
The gun has been fired.
Steady yellow light
The gun is charging
Yellow light flashing
CP fault
The red light is on
Overpressure and underpressure
The red light blinks once for 1S
The PE cable is not connected
The red light blinks once for 2S
The emergency stop switch is pressed
The red light 4S blinks once
Equipment overcurrent
The red light is on for 3S and then off
for 3S
Short circuit of equipment
The red light is on for 5 seconds and
then off for 5 seconds
Electrical leakage of equipment
The green and yellow lights blink once,
1S
Equipment overtemperature
The green and yellow lights flash once
for 2S
Adhesion of equipment
Green and yellow light 4S blink once
COMMON PROBLEMS AND SOLUTIONS
5. 0 The Display is black (LED indicator is off)
Cause: The AC inlet switch is not closed, and the AC inlet switch is
tripping.
Solution: Close the AC incoming wire switch again. If it trips all the time,
please check whether the wiring of the equipment is correct and the L or N
wire is connected to the PE terminal.
5.1 Dead Screen Symptom,no response occurs when you click the display
System failure:system delay or crash.
Solution: Press the emergency stop button of the device, and then turn
the emergency stop button clockwise after about 5 seconds; If the display