SHUTTER EXHAUST FAN USER MANUAL We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us.
SHUTTER EXHAUST FAN USER MANUAL NEED HELP? CONTACT US! Have product questions? Need technical support? Please feel free to contact us: CustomerService@vevor.com This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received.
PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USING THE EQUIPMENT Contents Ⅰ.SAFETY PRECAUTIONS Ⅱ.PRODUCT DESCRIPTION Ⅲ.INSTALLATION Ⅳ.POWERING AND SETUP Ⅴ.CLEANING Ⅵ.PROGRAMMING SAFETY PRECAUTIONS WARNING Read all safety warnings, instructions, illustrations and specifications provided with this electrical appliances. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.
If the machine emits smoke, odor, motor noise and other abnormal conditions,Please do not use it. It may cause fire or electric shock Do not disassemble, repair or rectify the machine during use. Doing so may result in fire or electric shock and personal injury BE CAREFUL DO NOT use fan in window. Rain may create electrical hazard. Do not damage or arbitrarily change the original power cord, and do not bend, forcibly pull, bind or press the power cord under heavy objects.
Disconnect the fan when removing grills for cleaning.Do not leave the fan running unattended. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
INSTALLATION TIPS!Prepare tools in advance: Small wrench,Hammer -5-
Fig.1. Before commencing assembly familiarize your self with all the assembly components and dimensions (See chart and diagram in Fig.1.) Installation method 1. The product shall be installed at least 3-5 meters above the ground for ventilation 2. Make a hole on the wall with the size of A2xB2. (Refer to Fig.1. ) 3. Punch four holes in the wall,You can choose four holes with the size of Chart A3 or four holes with the size of B3; (Refer to Fig.1.) 4.
6. Finally connect the lines correctly, (Refer to WIRING DIAGRAM) Note: Make sure the product is firm and the wiring is right before power on WIRING DIAGRAM POWERING AND SETUP Step 1: Plug the fan’s 3-pin connector into the universal controller’s out 1 or out 2 port signified by the fan/power symbol.Plug the sensor’s 4-pin connector into the controller’s sensor signified by the controller symbol.See the(Fig.3.) Fig.3.
an AC power outlet.See the(Fig.4.) Fig.4. Tips: Smart controllers with EC motors can support two fans of any size. The two EC-motor fans must be plugged in to an outlet to power the fans and the controller. See images below. Dual Connection EC models can connect two fans of any size CLEANING: 1.Be sure to unplug from the electrical supply source before cleaning. 2.Plastic parts should be cleaned with mild soap and damp cloth or sponge. Thoroughly remove soap film with clean water. 3.
PROGRAMMING BUTTON DESCRIPTION 1.MODE BUTTON Cycles through the controller's temperature/humidity programming: ON, OFF,TIMER, AUTO (4 triggers),and ALARM (4 settings). 2.UP / DOWN BUTTON Adjusts the settings of the mode that you are in. Up button raises and down button lowers. Hold both to turn off triggers. 3. LEAF BUTTON Turns the screen off while programs run in the background. Hold for two seconds to lock or unlock the LCD display. 4.
Displays the alerts and statuses from the controller, including the alarm and the screen lock. 7.PROBE HUMIDITY Displays the current humidity that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in. 8.FAN SPEED Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in. 9.SETTING Displays the value you set for the current mode. Pressing the up or down button changes the value.
to 1 if the device is left unattended for 30 seconds. Holding the up or down button will change the display’s units to F or C, respectively. TIMER MODE In this mode, pressing the up or down button will set the timer. The fan will ramp up to ON Mode’s setting until the timer’s clock runs out. It will begin spinning 5 seconds after the timer is set. Leaving the timer mode while it’s running will pause it until you return to this mode.
You may set this trigger below the low temperature trigger to create a range where the fan is active. Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode. TRIGGER MODE: LOW TEMPERATURE In this mode, pressing the up or down button sets the low temperature trigger. The fan will activate if the probe’s reading meets or falls below this trigger. It will gradually ramp up until it reaches the ON Mode’s setting.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode. TRIGGER MODE: HIGH HUMIDITY In this mode, pressing the up or down button sets a high humidity trigger. The fan will activate if the probe’s reading meets or exceeds this trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading falls below your trigger, the fan will turn off.
TRIGGER MODE: LOW HUMIDITY In this mode, pressing the up or down button sets the low humidity trigger. The fan will activate if the probe’s reading meets or falls below the trigger. It will gradually ramp up until it reaches the ON Mode’s setting. If the probe’s reading rises above your trigger, the fan will turn off. We recommend turning this trigger OFF when not in use during set up by holding the up and down buttons together.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller. ALARM SETTING: LOW TEMPERATURE In this mode, pressing the up and down button sets a low temperature alarm. The alarm will sound and its icon will flash if the probe’s reading falls below the set temperature. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading rises above the trigger or if any button is pressed.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller. ALARM SETTING: HIGH HUMIDITY In this mode, pressing the up and down button sets a high humidity alarm. The alarm will sound and its icon will flash if the probe’s reading exceeds the set humidity. To activate the alarm, leave the alarm mode. The alarm will turn OFF if the probe’s reading falls below the trigger or if any button is pressed.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller. FAHRENHEIT OR CELSIUS To switch between Fahrenheit and Celsius readings, set the controller to OFF Mode. Hold the up button to switch to Fahrenheit (°F) and the down button to switch to Celsius (°C). DISPLAY BRIGHTNESS To adjust the brightness of the display, set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level.
will not be able to switch modes or adjust settings. You will only be able to put the controller in ECO display. Holding the LEAF button for three or more seconds will unlock the controller. ECO-MODE To turn off the LCD display, press the LEAF button. While the screen is off, all programs, settings, and alarms will run in the background. You can activate ECO Mode while the controller is locked. To exit ECO mode, press any button. ALERT ICONS The top left of the display shows the alert icons.
CHECK FAN ALERT This icon will flash when the fan's probe senses interference to its functioning. Check the fan for possible issues. If the fan is not heating up, please see the warranty page for replacement information. Manufacturer: Bote electric appliance(Guangdong)Co.,Ltd Address: 5TH floor,No.
E-mail: CustomerService@vevor.