Instructions / Assembly

A2
Inverter (0.75-30kW)
Content
ERROR
FWD
Description
Fault indicator.
Clockwise rotation indicator.
REV
Anticlockwise rotation indicator.
Analog input frequency indicator.
ANALOG
SEGMENT Segment input frequency indicator.
PANEL
Digital
tube
Panel input frequency indicator.
Inverter runtime frequency. If inverter stops, it flashes.
The display data is given by “Pn01” data.
Chapter 4 Parameter Set Method
4.1 Parameter set and modification
Set parameter when inverter is stopped and the parameter is not
locked (Pn32=1). First, enter parameter set menu by push button
“SET”. Second, push button /to choose the certain item. Third,
push button “SET” again to enter the item. Fourth, push button /
to choose certain bit and push /to modify the value. Finally,
push button “SET” to save the new parameter or push button “STOP”
to parent menu without any saving.
Push button “SET” to save the new parameter or push
button “STOP” to parent menu without any saving.
4.2 Button notice
When modify parameters, long push
/
to rolling number
of current bit between 0-9.
8