Instructions / Assembly
A2
Inverter (0.75-30kW)
Pn 23
Pn 24
Pn 25
Pn 26
Pn 27
Pn 28
Multi-segment speed 4 frequency:
000.10 Hz—400.00Hz
Multi-segment speed mode 4-segment frequency
Multi-segment speed 5 frequency:000.10 Hz—400.00Hz
Multi-segment speed mode 5-segment frequency
Multi-segment speed 6 frequency:000.10 Hz—400.00Hz
Multi-segment speed mode 6-segment frequency
Multi-segment speed 7 frequency:
000.10 Hz—400.00Hz
Multi-segment speed mode 7-segment frequency
Point move frequency:
000.10 Hz—400.00Hz
Point move frequency
Choice of relay output:1—6
1
3
5
Stop inverter
Inverter fault
Frequency decreasing 6 Frequency reached
2 Run inverter
4 Frequency increasing
If output condition is satisfied, ON/OFF states reverse.
Pn 29
Pn 30
Pn 31
2rd acceleration time:000.01S-650.00S
2
rd acceleration time
2rd deceleration time:
000.01S
-
650.00S
rd deceleration time
2
2rd deceleration stop frequency:000.10 Hz—400.00Hz
When runtime frequency is larger than this value,
acceleration/deceleration time is defined by Pn08,Pn09
When runtime frequency is smaller than this value,
acceleration/deceleration time is defined by Pn29,Pn30
As shown in Figure:
1
5