Instructions / Assembly
A2
Inverter (0.75-30kW)
Chapter 7 Description of Configure Parameters
Pn 01
Default display content:1——30000
RUN: 1 means it will display runtime frequency
Otherwise, it displays motor’s synchronization speed.
2——30000 is motor synchronization speed
STOP
:
it will display frequency given by external signal.
Pn 02
Pn 03
Initial startup frequency by panel or other method
Range
:
000.01Hz
-
400.00Hz
,
the initial panel data and
external signal frequency during startup
.
Source of runtime frequency with range:1—7
1
3
5
7
Potentiometer
2 Panel button
4 External 0-10V signal
6 External digital signal
External 0-5V signal
External 0-20mA signal
Multi-segment signal
Pn 04
Pn 05
Source of runtime command with range:1—2
Panel button control 2 External signal control
1
clockwise / anticlockwise disable with range:
1—3
1
3
clockwise enable only
clockwise / anticlockwise enable
2 anticlockwise enable only
Pn 06
Pn 07
Method to stop inverter with range:
1—2
stop by itself 2 stop by deceleration
1
Start again by external signal with range:
1—2
disable 2 enable
1
Description: when the power on the external operation of
the signal is allowed to start effectively.
Pn 08
Acceleration time with range:000.01S-650.00S
Accelerate time (from 0Hz to Pn10).
1
2