Technical data

41
Impeller inspection
Inspect the impeller for damage.
Replace the impeller if necessary.
Re-install the impeller
The impeller should be lubricated with
glycerin or a non-petroleum based lubri-
cant such as a silicone spray before fit-
ting it into the impeller housing.
Fit the impeller to the pump shaft. (if an
existing impeller is re-used, install it in
the same position as removed).
Replacing the pump cover
Replace the cover with a new gasket.
Check the water filter and open the sea
cock.
Raw water pump inspection
Every 1000 operating hours.
Maintenance
VD00127 VD00004 VD00156
iMpeller, art.Code: stM8061 Gasket, art.Code: stM8002