Product Manual
Table of Contents Rev. 9/13/2019 LL-PMPS MANUAL
Table of Contents Copyright 2019 Vestil Manufacturing Corp. Page 11 of 22
ELECTRICAL BOX (ITEM NO. 2 ON P. 10)
Item
Part no.
Description
Qty.
1
71616
10 – 32 x
5
/
8
” TSHMS screws 4
2
01-129-001 Transformer 1
3
132560
Motor contactor
1
4
27531
10 – 32 x
1
/
4
” PSHMS zinc-plated
screws
4
5
32028
8 – 18 x
1
/
2
” HWH TEK drill and tap
screws
4
6
99-034-941
Aluminum din rail
3”
7
01-029-006
5
/
16
” – 18 x 1” utility grade bolt
1
8
99-029-142 6” x 6” enclosure plate 1
9
99-034-037
3
/
8
” (
1
/
2
” knockout) Romex 2-screw
NM clamp connector
4
10
01-127-010
LHL standard manifold, 3” boss
1
11
99-116-033
3
/
8
” – 16 x 1” utility grade bolt
2
12
99-153-011
Check valve
1
13
99-144-023 O-ring 1
14
99-144-022
O-ring
1
15
99-153-015
Normally closed cartridge valve
1
16
99-034-008
24VAC coil
1
17
99-153-006 Pressure relief valve 1
18
99-144-007
O-ring
1
19
99-531-005 Filter 1
20
99-153-038
Flow control, 1.0GPM
1
MANIFOLD (ITEM NO. 12 ON P. 10)
115VAC MODULAR POWER UNIT ELECTRICAL CIRCUIT DIAGRAM
NOTE: THIS DIAGRAM APPLIES T UNITS BUILT BEFORE DEC. 1, 2018. UNITS MANUFACTURED ON OR AFTER
DEC. 1, 2018, RECEIVE 2
ND
GENERATION MODULAR POWER UNITS (MPU-GEN2). SEPARATE
INSTRUCTION MANUALS ARE PROVIDED FOR THESE POWER UNITS.
Limit switch or jumper wire
used where applicable.
NOTE:
Overcurrent &
short-circuit
protection as well
as system
disconnect must
be provided.
NOTE: THIS DIAGRAM APPLIES T UNITS BUILT BEFORE
DEC. 1, 2018. UNITS MANUFACTURED ON OR
AFTER DEC. 1, 2018, RECEIVE 2
ND
GENERATION
MODULAR POWER UNITS (MPU-GEN2). SEPARATE
INSTRUCTION MANUALS ARE PROVIDED FOR
THESE POWER UNITS.