Step 6: Disconnect the FRC from the mounting plate. The FRC mounts on the plate with 2 Phillip’s head bolts
and 5/16 inch nuts. After the bolts are unfastened, remove the FRC.
5/16 inch
nuts
Step 7: The FRC may not need to be replaced if the malfunction results from mechanical binding of some of the
moving parts. To apply lubricant, remove the plastic caps shown below (identified with arrows) with a flat-
blade screwdriver.
Side View
Remove
plastic caps
Apply lubricant
Step 8: Install the replacement FRC by performing Steps 1 through 7 in reverse order. Similarly, if you simply
lubricated the original FRC, perform steps 1, 2, 3, 6 and 7 in reverse order.