Instructions for Changing the Motor Controller
Estimated time required: 30 minutes
Tools Required:
2x 14mm wrench, open face;
Philips head screwdriver;
8mm wrench or adjustable crescent wrench.
Only trained, authorized personnel should perform maintenance on this equipment. Lead acid
batteries present hazards to the person(s) working on, with, or in the vicinity of them. To minimize the risk of serious
personal injury, read every one of the instructions and DO NOT proceed with maintenance unless you understand
each of them.
Lock out all potential energy sources before attempting this installation according to OSHA lockout/tagout
procedures (29 CFR 1910.147); turn off the unit and remove the key.
DO NOT work on, with, or in the vicinity of the battery UNLESS you are wearing personal protective equipment,
particularly a face shield. Batteries contain sulfuric acid and produce explosive gases. A battery explosion could
result in loss of eyesight or serious burns.
DO NOT smoke near the battery or expose the battery to sparks or flames.
Charge batteries ONLY in clean, dry, and well-ventilated locations.
DO NOT lay tools or anything metallic on top of a battery.
Remove personal items like rings, bracelets, necklaces, and watches BEFORE beginning to work on the battery.
The battery can produce energy sufficient to weld jewelry to metal; underlying skin could be severely burned.
Keep fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. Immediately rinse any
skin that has been contacted by acid. If acid gets in your eyes, rinse them thoroughly with eye wash. After
rinsing the affected area, notify your supervisor about the incident.
DO NOT expose the unit or the charger to rain or other adverse conditions. ALWAYS return the unit to its
designated storage location when you finish using it. The designated storage location should offer protection from
the elements and should not interfere with or obstruct traffic.
Replace defective cords or wires immediately.
Routinely check the water level in the battery.
Make sure the battery charger is unplugged from the 115V source BEFORE driving the unit.
Operating the pallet truck when battery voltage is low can cause premature motor contact failure.
Turn off power to the unit and remove the key.
Step 1: Remove the screws (2) shown below; then remove the yellow cover. The battery charger is located on the
left side of the unit; the Campro motor controller is adjacent to the charger and is identified with an arrow in Photo
2 below.
1