Technical information
5
US
Installation.
See drawings - page A and B.
Install the cabinet in a dry place and so that
it is not exposed to direct sunlight or any
other sour ce of heat.
Place the cabinet in a level position. This is
easily achieved by adjusting the adjustable
feet at the front edge of the base.
The cabinet may not rest against a wall on
its hinged side. When placing the cabinet
on a carpet or on a wooden oor you should
adjust it once more after some time as the
cabinet might settle in soft foundati ons.
If you want to build the appliance into a
cupboard you must consider 3 factors:
1. There must be space above the appli-
ance in order to make the cooling system
work satisfactorily.
2. When the door is opened the appliance
takes up more room in the width and
therefore the door must either be placed
outside the cupboard or there must be
a space of at least 0,6 inch at the hinge
side.
3. The distance to the wall at the hinge side
must be of a sufcient size.
.
Furthermore it is possible to build together
two appeliance. If one of these is a wine
cabinet please observe a min. distance of
25mm between the cabinet in order to keep
cooling performance intact.
It is safest to place the earthed wall socket
abo ve the appliance and at least 79 inch
above the oor. Any local installation rules
for appliances of this kind must be ob-
served.
Electrical connection.
The technical marking of the appliance can
be seen from the rating plate.
Important: Wiring and connections in
power supply systems must been all appli-
cable (local and national) electrical codes.
Consult these codes lengths and sizes prior
to cabinet installation.
Power supply:According to UL 471 this
equipment is intended for connection to a
maximum 15 ampere 120v olt single-phase
branch circuit.
Maximum fuse size 10 Amps.
This appliance is equipped with a three-
prong (ANSI type 5-15P grounded) plug for
your protection against shock hazards. The
appliance should bee plugged in to properly
grounded three-prong receptacle
Do not under any circumstances cut or
remove the round grounding prong from the
appliance plug.
Do not under any circumstances use exten-
sion cords
Max. 36 kg