Technical information
Appendix B – Development Environment Setup – Without DHCP
It’s recommended that you use Windows XP Professional with your development station. In this
setup, eBox-2300 is connected directly to the development station’s Ethernet port using a
Crossover RJ45 Ethernet cable.
A NULL serial cable linking between one of the development station’s COM port with eBox-
2300’s COM1 provides additional debug information.
When eBox-2300 is connected directly to the development station as above, the IP address for
the development station must be configured correctly for it to work.
When working with this setup method, 192.168.2.232 is the preset static IP address for eBox-
2300.
The development workstation’s IP address needs to be set correctly for this to work.
Following is the IP address setting guideline for the development station.
IP address: 192 . 168 . 2 . xxx (must be different from eBox-2300’s IP address)
Subnet mask: 255 . 255 . 255 . 0
If the IP address is not setup correctly, eBox-2300 will not able to communicate with the
development station.
eBox-2300 Windows Embedded CE 6.0 JumpStart rev 3.5 Page 45 of 53