Installation guide

Trunk timing values 34-6
Chapter 34: Trunk Settings
Wave Global Administrator Guide
The following table describes the different types of outbound T-1 trunk timers for E&M Wink
Start and E&M Immediate Start signaling types.
Outbound T-1 trunk timers (E&M Wink Start and E&M Immediate Start)
Display Name Description Default Value
(msec)
Error Duration
Length of time-out after an error before the
channel is put back in service
30000
Far-End
Disconnect
Time to wait to determine that far end has
disconnected
250
Near-End
Disconnect
Time to wait after near-end hangs up for far-end
to hang up before treating the situation as an
error
700
Wait Answer
Maximum wait for answer 0 (infinite)
Validate Answer
Minimum length of incoming off-hook to detect
answer
600
Maximum Wink
Maximum duration of incoming wink allowed.
Timeout is interpreted as GLARE
280
Validate Start
Signal (applicable
to E&M Wink Start
only)
Minimum duration of wink 70)
Wait Start Signal
(applicable to
E&M Wink Start
only)
Maximum wait for wink after near-end
disconnects
5000
Wait Dial
Delay before dial after end of wink 100 (E&M Wink Start)
200 (E&M Immediate
Start)
DTMF Duration
(applicable to
E&M Wink Start
only)
Duration of DTMF tone on and off 100
Release 2.0
September 2010