Installation guide
Trunk timing values 34-5
Chapter 34: Trunk Settings
Wave Global Administrator Guide
Trunk timing values
You can find the Trunk Timers in the Trunk Configuration applet.
T-1 trunk timing values
The following table describes the different types of inbound T-1 Trunk timers for the E&M
Wink Start and E&M Immediate Start signaling types.
Inbound T-1 trunk timers (E&M Wink Start and E&M Immediate Start)
Display Name Description Default Value
(msec)
Hit Counter Limit
Not an actual timer, but a counter used to
determine a rare condition where a test signaling
pattern is being sent by the service provider. If
the counter is exceeded, the channel enters an
error state.
10
Answer Delay
Minimum delay before answer 70
Inter-Digit
Maximum wait for next digit 15000
Wink Duration
(applicable to
E&M Wink Start
only)
Duration of transmit wink 190
Far-End
Disconnect
Time to wait to determine that far-end has
disconnected
300
Call Validate
Time to wait to determine that far-end has
disconnected; delay before transmit wink
90
Near-End
Disconnect
Time to wait after near-end hangs up for far-end
to hang up before treating the situation as an
error
300
Release 2.0
September 2010