Installation guide
ISDN agent 32-20
Chapter 32: SNMP Agents
Wave Global Administrator Guide
The Signaling Group
The Signaling Group is used to control D (delta) channels. The Signaling Group consists of
three tables:
• The Signaling Table contains configuration and operational parameters for the Terminal
Endpoint layer interface of each D channel.
• The Signaling Stats Table contains statistical information for the same interfaces.
• The LAPD table contains configuration and statistical information for each D channel
Data Link layer (LAPD) interfaces of the system.
Note: The Directory Group, used to specify a list of directory numbers for each signaling
channel, is not currently implemented.
Signaling Table
MIB Variable Access Definition Syntax Value
visdnSignalingIfIndex
R The ifIndex value of the interface
associated with this signaling channel.
Integer
1-65535
visdnSignalingProtocol
R The particular protocol type supported
by the switch providing access to the
ISDN network to which this signaling
channel is connected.
Isdn
Signaling
Protocol
1 = Other
2 = Ds1
25 = Swissnet3
visdnSignalingCallingAddress
R The ISDN address to be assigned to
this signaling channel.
String
visdnSignalingSubAddress
R The ISDN subaddress to be assigned to
this signaling channel.
String
visdnSignalingBchannelCount
R The total number of B channels
managed by this signaling channel.
Integer
1-65535
visdnSignalingInfoTrapEnable
R Indicates whether
isdnMibCallInformation traps should
be generated for calls on this signaling
channel.
Integer 1 = Enabled
2 = Disabled
Release 2.0