Fault Monitor Group
The Fault Monitor Group contains information about the fault monitor status. This group
contains just one object, described below.
Trap Info Group
The Trap Info Group contains information about the last fan, power supply, and fault monitor
traps.
Environment SNMP agent - Fault Monitor group
MIB Variable Access Definition Syntax Value
i
oFaultMonitorStatus R Describes the operational status of the Fault
Monitor. Valid values are:
NotResponding. Fault monitor is not
responding
ModemFailed. Fault monitor modem
has failed
OK. Normal operational state
Integer 1 = RAMFull
2 = NotResponding
3 = OK
4 = ModemFailed
Environment SNMP agent - Trap Info Group
MIB Variable Access Definition Syntax Value
ioLastFanTrap
R This object describes, in more detail, the last fan
trap event that occurred. Since traps for all fans
are combined into one trap, this string describes
each fan status just after the trap condition.
String
ioLastPowerSupplyTrap
R This object describes, in more detail, the last
power supply trap event that occurred. Since
traps for all power supplies are combined into
one trap, this string describes each power supply
status just after the trap condition.
String
ioLastFaultMonitorTrap
R This object describes, in more detail, the last fault
monitor trap event that occurred. Since traps for
all fault monitor events are combined into one
trap, this string describes each event (RAMFull,
NotResponding, or ModemFailed) that caused
this trap.
String