Installation guide

Configuring site-to-site call routing for IP telephony 6-13
Chapter 6: IP Telephony Configuration
Wave Global Administrator Guide
For more information about Caller ID, see “Configuring Caller ID” on page 16-6.
8 On the SIP Settings tab, define authentication and registration settings for this SCP.
Enter the following information:
User Name. 1-32 alphanumeric character name that identifies this SCP. Each SCP’s
user name must be unique and cannot match any users extension.
Proxy Server. ITSP address, or the address of another Wave Server Server to which
this SCP is registering.
Port. The default port number is 5060. This port is generally used for IP telephony,
but if this port is in use in your system, you can specify another port.
Release 2.0
September 2010