Configuring digital trunks and channels 5-26
Chapter 5: Configuring Analog and Digital Trunks
Wave Global Administrator Guide
• NPI Name. A text string describing the Numbering Plan Identifier; typically E.164,
Unknown, or Private.
•
TON #. Type of Number. There can only be four different types of entries:
•
0 = unknown.
•
1 = international number.
•
2 = national number.
•
4 = subscriber number.
•
TON Name. A text string describing the Type of Number; typically National,
International, or Unknown.
•
Service/Feature. Service vs. Feature. Typically left N/A unless the provider states that
it should be either Service or Feature.
• If you select Service or Feature, you need to configure the next three settings:
BFCV #. Binary Facility Coding Value, 0 through 31.
A number for the service must be entered in the BFCV field. The provider provides
this number. The number can be from 0 through 31.
Some common Service IDs:
•
1 = SDN (including GSDN) = in/out.
•
2 = Toll free MEGACOM= in.
•
3 = MEGACOM = out.
•
6 = ACCUNET Switched Digital Service = in/out.
•
7 = Long Distance Service = in/out.
•
8 = International Toll Free Service = in.
•
10 = ATT MultiQuest = in.
•
17 = Call Redirection Service = in.
BFCV Name. A text string describing the BFCV value.
SID #. Service Identifier, 0 through 127. Used primarily by Bell Canada.
If you are not sure of your changes, click
Restore System Defaults to restore your
changes to the system defaults.
Release 2.0