Installation guide
Configuring analog trunks 5-19
Chapter 5: Configuring Analog and Digital Trunks
Wave Global Administrator Guide
In both cases, the Customize Impedance dialog opens.
Depending on how you accessed this dialog, different default values will be displayed:
• From the Customize Locale dialog, the defaults reflect valid combinations of
pre-defined data for the selected Locale.
• From the Trunk Configuration applet, pre-defined system values are displayed.
2 Specify the following information:
•
ACIM Value. Specifies the terminating impedance that Wave analog trunks present to
the CO.
ACIM Value is location-specific and generally does not need to be changed.
For North America, the correct value is 0, which sets the Wave trunk terminating
impedance to 600 Ohms. Other locale-specific defaults may have different values.
Note: This value is not the same as the value displayed in the CO Termination field.
Release 2.0
September 2010