System information

APPENDIX J. TELEVANTAGE CONFIGURATION SETTINGS J-39
Server\CPAConnectDelay
DWORD value that specifies the delay in milliseconds after call progress analysis
returns the connected result before marking an outbound call as connected. Increasing
this value may help discriminate between abandoned and connected calls.
Default value is
2000 millseconds.
Server\AllowCallsWithoutUsers
DWORD value that specifies whether or not to allow conference calls with no users
(that is, all parties have left the conference) and external transfers of external calls.
Default value is
1 (true.) A value of 0 would prevent conference calls with no users and
external transfers of external calls.
Server\AllowGatewayUserLogin
DWORD value. If this value is non-zero, the system will allow Gateway users to log in
from an auto attendant or internal dial tone. Gateway users inherit the permissions of
their Enterprise Gateway and usually have the ability to dial external numbers while
logged in on a trunk.
Default value is
1.
Server\AudioControlRingtimeout
DWORD value that specifies the maximum time (in milliseconds) that the TVAudio
Control will spend attempting to connect before returning with a timeout.
Default value is
30000 milliseconds.
Server\CallRecordingBeepFile
Specifies the filename of the file containing the sound used as a reminder beep during
call recordings (see “Including a beep on call recordings” in Chapter 4 in Administering
TeleVantage.) By default the file is
StdCallRecordingBeep.vox, which produces a 500
millisecond beep. TeleVantage provides an alternate file called
ShortCallRecordingBeep.vox, which produces a 200-millisecond beep. Both beeps
have a frequency of 1400 Hz with a 25% amplitude. You can specify your own filename
as long as the file resides in the default prompt directory (by default,
C:\Program
Files\TeleVantage Server\Vfiles
.)
See CallRecordingBeepInterval for the spacing between beeps.
Default value is
StdCallRecordingBeep.vox
Server\CallRecordingBeepInterval
The time (in milliseconds) between reminder beeps on call recordings. The beep
interval will never be less than the duration of the beep sound file
(
CallRecordingBeepFile) plus one second, regardless of what is entered here.
Default value is
15,000 milliseconds (15 seconds.)
System database settings