System information

J-32 INSTALLING TELEVANTAGE
Add the following for each PRI board in your system, under:
HKLM\SOFTWARE\Artisoft\TeleVantage\Server\DTIBoard1\GlobalCall
Q CIDNameOnSetup (DWORD.) Message that contains the calling name field. When set
to
0, calling name is delivered in the FACILITY message. When set to 1 (the default),
calling name is delivered in the SETUP message.
Q CIDNameIE (DWORD.) IE in which the calling name field is delivered. default is 28
(0x1C.)
Q CIDNameOffset (DWORD.) Offset within the IE where the calling name field begins.
Default is
14 (0x0E.)
Q CIDNameLength (DWORD.) Length of the calling name field within the IE. Default is
15 (0x0F.)
Q CIDNameTimeout (DWORD.) Used only when CIDNameOnSetup = 0. Maximum
length of time TeleVantage waits for the FACILITY message to arrive. The default,
2000, specifies a 2-second wait.
The following is a sample IE taken from a TeleVantage Server log that conforms to the default
CIDNameIE, CIDNameOffset, and CIDNameLength values described above. The IE is
displayed in hexadecimal and ASCII:
IE: 0x1C: 9F 8B 01 00|A1 17 02 01|01 02 01 00|80 0F 52 4F|42 42 49 4E|53 20 45 4E|47 49 4E 45|45
"....!.........ROBBINS ENGINEE"
BRI board settings
HKLM\SOFTWARE\Artisoft\TeleVantage\Server\BRIBoard<n>\ISDN
\Server\BRIBoard<n>\ISDN
DumpCallInfo
DWORD value specifying whether or not to include raw call-event information
elements from BRI trunks in the TeleVantage Server log (filename format
Tvlogxxx.txt.)
Default is
0, which suppresses the information element logging. Set to 1 to include the
information elements in the log.
DNISWaitTime
DWORD value specifying the expected DNIS (DDI) time (in milliseconds) that the
TeleVantage Server will wait for digits to be received before attempting to process the
inbound call.
Default is
2000 milliseconds (2 seconds) after it receives the notification of an inbound
call.