Technical data
Digit Conversion 3-73
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
ADMIN PROGRAMMING
Station
Differential Ring (PGM 124 - FLEX 3-4) … see details on page A-28
Digit Conversion
When a User dials digits, the dialed digits are converted according to the Digit Conversion Table
before the Numbering Plan is checked. Digit conversion is performed on outside incoming CO
calls, in addition to converting User dialed digits.
CONDITIONS
- Time Zone for Digit Conversion - The pressed digits can be converted into a different
digit stream according to the time zone: Always, Day/Night/Timed zone, and LCR
Day/Time zone. There can be up to 9 conversion matrices in the LCR Day/Time zone,
while 3 conversion rules are possible in the Day/Night/Timed zone. Digit conversion is
performed only when there is a conversion rule that applies based on the specific time
the digits are pressed.
- Dummy CO Dial Tone - The CO line is seized following digit conversion Therefore, it is
impossible to receive a CO dial tone when digit conversion is programmed. To remove
any inconveniences of users, the system can be configured to provide a dummy CO
dial tone after one of the dialed digits is pressed.
- Digit information Display Before or After Conversion - Each Station can be
programmed to display either the dialed digits or the digits after conversion. SMDR
also can print either dialed digits or the digits after conversion.
CONDITIONS
- Each DN and CO line can be set to have one of 9 digit conversion Tables.
- There are 300 entries for each digit conversion table.
- The Digit Conversion Table allows up to 16 digits to be programmed as 'dialed digit'
and 'converted digit'.
PGM 124 BTN RANGE DEFAULT
ICM DIFF RING ID -- set the intercom differential ring ID – usually 1-4
is valid.
3 000-254 On
CO DIFF RING ID -- set the CO line differential ring ID – usually 1-4
is valid.
4 000-254 Off
Release 1.0