Technical data

Dialing Restrictions 3-65
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
CO Line Data
Toll Exception Table (PGM 250) … see details on page A-106
RELATED FEATURES
Temporary Station COS/Lock … see page 3-68
Walking COS … see page 3-70
Day/Timed & Night Station COS
CO Line Toll Exception can be applied differently in Day/Night/Timed mode at each Station. The
service mode is generally controlled by the Attendant group member, and based on the mode,
appropriate dialing privileges are established.
CONDITION
If COS is set to 0, only intercom calls can be placed; CO line access is disabled.
If COS is set to 1, there are no restrictions.
OPERATION
System
Dialing restrictions are automatically applied based on COS assignments:
ADMIN PROGRAMMING
Station Data
Station COS (PGM 137) … see details on page A-39
PGM 250 BTN RANGE DEFAULT
ALLOW TABLE -- allow digits. 1 Max 16 digits -
DENY TABLE -- deny digits. 2 Max 16 digits -
TENANT -- Tenant groups to apply the table entry. 3 1-9 (MBX IP 300)
1-5 (MBX IP 100)
-
PGM 137 BTN RANGE DEFAULT
DAY COS -- Station’s COS in Day mode. 1 00-15 1
NIGHT COS -- Station’s COS in Night mode. 2 00-15 1
TIMED COS -- Station’s COS in Timed mode. 3 00-15 1
Release 1.0