Technical data
Data Line Security 3-56
Chapter 3: System Features
MBX IP Description / Operations & Programming Guide
Data Line Security
Data transmitted over CO lines is subject to distortion and errors if system tones such as
Camp-On, Call Wait and Override are applied during transmission. To eliminate such errors,
stations that use analog data (modems or Fax) can be assigned to block incoming system
tones.
CONDITIONS
- Stations or an Attendant attempting to Camp-On or Override a station with Data Line
Security will receive an error tone.
- When Data Line Security is enabled, the system will not apply audio gain to the call.
OPERATION
System
When Data Line Security is assigned, System tones are automatically blocked.
ADMIN PROGRAMMING
Station Data
Data Line Security (PGM 123 - FLEX 6) … see details on page A-27
Delayed CO/IP Ring
Determines if the CO/IP Ringing will be sent immediately on receipt, or delayed. The delay can
be up to 30 system ring cycles, allowing other stations to answer the call.
CONDITIONS
- Delay Ring can be assigned for a station.
- The station will receive immediate ringing, if no delay is entered when programming
Ring assignments.
- If stations are assigned for immediate ring, the call will be routed using the incoming
CO Alternate programming.
- The delay is applied only when ring service type is ‘Ring-RING’.
PGM 123 BTN RANGE DEFAULT
DATA SECURITY -- disables override and camp-on tones to the
station to avoid occurring error when sending data.
6 0: Off
1: On
Off
Release 1.0
November 2010