Technical data

DEFAULT VALUES B-54
Appendix B: Quick Reference
MBX IP Description / Operations & Programming Guide
Timed Forward Type 5 0: Not Used
1: Unconditional
2: Busy
3: No-Answer
4: Busy/No-Answer
Not Used
Timed Forward Destination 6
STATION DATA
SYSTEM TIMER I A-85 220
CO-to-CO Transfer Timer 1 000-300 (1sec) 30
Hot-Desk Logout Timer 2 00-24 (1hour) 0
ACNR Pause Timer 3 5-300 (1sec) 30
Paging Timeout Timer 4 0-300 (1sec) 15
Pause Timer 5 1-9 (1sec) 3
Voice Mail Pause Timer 6 1-9 (1sec) 3
VMIB Message Minimum Record Timer 7 1-9 (1sec) 4
VMIB Message Maximum Record Timer 8 1-999 (1sec) 60
Call Wait Warning Timer 9 10-180 (1sec) 30
Camp-On Warning Timer 10 10-180 (1sec) 30
CCR Inter-Digit Timer A-85 220 11 1-30 (1sec) 3
Web Password Guard Timer 12 1-999 (1min) 5
SYSTEM TIMER II A-86 221
SLT Hook Switch Bounce Timer 1 1-25 (100msec) 1
SLT Maximum Hook Flash Timer 2 1-25 (100msec) 5
SLT Minimun Hook Flash Timer 3 0-250 (100msec) 20
LCO Ring ON Timer 4 1-9 (100msec) 2
LCO Ring OFF Timer 5 10-150 (100msec) 60
LCO Release Guard Timer 6 1-150 (100msec) 10
SYSTEM TIMER III A-87 222
Door Open Timer 1 5-99 (100msec) 20
Message Wait Alert Tone Timer 2 0-60 (1min) 0
PROGRAM GROUP PG # PGM BTN RANGE DEFAULT
Release 1.0